著者
Shinji Naganawa Rintaro Ito Toshiaki Taoka Tadao Yoshida Michihiko Sone
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.bc.2021-0141, (Released:2021-12-25)
参考文献数
16
被引用文献数
1

It has been reported that perivenous cystic structures near the parasagittal dura are associated with the leakage of gadolinium-based contrast agents at 4 hours after intravenous administration. The origin of such cystic structures remains unknown. While reading many cases of MR cisternography, we noticed that some of the cystic structures appeared to connect to the perivenous subpial space. This new imaging finding might facilitate future research of the waste clearance system for the central nervous system.
著者
Mitsunori Matsumae Jun Nishiyama Kagayaki Kuroda
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.rev.2021-0116, (Released:2021-12-09)
参考文献数
229
被引用文献数
15

One of the major issues in the surgical treatment of gliomas is the concern about maximizing the extent of resection while minimizing neurological impairment. Thus, surgical planning by carefully observing the relationship between the glioma infiltration area and eloquent area of the connecting fibers is crucial. Neurosurgeons usually detect an eloquent area by functional MRI and identify a connecting fiber by diffusion tensor imaging. However, during surgery, the accuracy of neuronavigation can be decreased due to brain shift, but the positional information may be updated by intraoperative MRI and the next steps can be planned accordingly. In addition, various intraoperative modalities may be used to guide surgery, including neurophysiological monitoring that provides real-time information (e.g., awake surgery, motor-evoked potentials, and sensory evoked potential); photodynamic diagnosis, which can identify high-grade glioma cells; and other imaging techniques that provide anatomical information during the surgery. In this review, we present the historical and current context of the intraoperative MRI and some related approaches for an audience active in the technical, clinical, and research areas of radiology, as well as mention important aspects regarding safety and types of devices.
著者
Ryota Hyodo Yasuo Takehara Takashi Mizuno Kazushige Ichikawa Shinya Yokoyama Yoji Ishizu Shinji Naganawa
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.ici.2021-0110, (Released:2021-12-09)
参考文献数
11
被引用文献数
3

A man in his 50s with Budd-Chiari syndrome diagnosed with the suprahepatic inferior vena cava (IVC) obstruction on CT was assessed using 4D Flow MRI before and after balloon angioplasty. 4D Flow MRI acquired in two respiratory phases, depicted complex hemodynamic and respiratory variability, and a jet stream at the narrowed channel of the membranous IVC. Post-interventional 4D Flow MRI showed that the IVC blood flow increased with corrected flow directions in the infrarenal IVC.
著者
Akira Kunimatsu Koichiro Yasaka Hiroyuki Akai Haruto Sugawara Natsuko Kunimatsu Osamu Abe
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.rev.2020-0159, (Released:2021-03-10)
参考文献数
79
被引用文献数
8

Texture analysis, as well as its broader category radiomics, describes a variety of techniques for image analysis that quantify the variation in surface intensity or patterns, including some that are imperceptible to the human visual system. Cerebral gliomas have been most rigorously studied in brain tumors using MR-based texture analysis (MRTA) to determine the correlation of various clinical measures with MRTA features. Promising results in cerebral gliomas have been shown in the previous MRTA studies in terms of the correlation with the World Health Organization grades, risk stratification in gliomas, and the differentiation of gliomas from other brain tumors. Multiple MRTA studies in gliomas have repeatedly shown high performance of entropy, a measure of the randomness in image intensity values, of either histogram- or gray-level co-occurrence matrix parameters. Similarly, researchers have applied MRTA to other brain tumors, including meningiomas and pediatric posterior fossa tumors.However, the value of MRTA in the clinical use remains undetermined, probably because previous studies have shown only limited reproducibility of the result in the real world. The low-to-modest generalizability may be attributed to variations in MRTA methods, sampling bias that originates from single-institution studies, and overfitting problems to a limited number of samples.To enhance the reliability and reproducibility of MRTA studies, researchers have realized the importance of standardizing methods in the field of radiomics. Another advancement is the recent development of a comprehensive assessment system to ensure the quality of a radiomics study. These two-way approaches will secure the validity of upcoming MRTA studies. The clinical use of texture analysis in brain MRI will be accelerated by these continuous efforts.
著者
Shinji Naganawa Rintaro Ito Toshiaki Taoka Tadao Yoshida Michihiko Sone
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.bc.2019-0099, (Released:2019-10-15)
参考文献数
11
被引用文献数
35

We currently obtain pre- and post-contrast enhanced whole brain 3D-real inversion recovery images for the evaluation of endolymphatic hydrops. We noticed that the space between the pial sheath surrounding the cortical veins and the cortical venous wall is enhanced and this enhancement seems to connect to the meningeal lymphatics along superior sagittal sinus. This new anatomical concept regarding the outflow from the glymphatic system might be important for the future research in neuroscience.
著者
Utaroh Motosugi Diego Hernando Curtis Wiens Peter Bannas Scott. B Reeder
出版者
日本磁気共鳴医学会
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2016-0081, (Released:2017-02-13)
参考文献数
47
被引用文献数
9

Purpose: To determine whether high signal-to-noise ratio (SNR) acquisitions improve the repeatability of liver proton density fat fraction (PDFF) measurements using confounder-corrected chemical shift-encoded magnetic resonance (MR) imaging (CSE-MRI).Materials and Methods: Eleven fat-water phantoms were scanned with 8 different protocols with varying SNR. After repositioning the phantoms, the same scans were repeated to evaluate the test-retest repeatability. Next, an in vivo study was performed with 20 volunteers and 28 patients scheduled for liver magnetic resonance imaging (MRI). Two CSE-MRI protocols with standard- and high-SNR were repeated to assess test-retest repeatability. MR spectroscopy (MRS)-based PDFF was acquired as a standard of reference. The standard deviation (SD) of the difference (Δ) of PDFF measured in the two repeated scans was defined to ascertain repeatability. The correlation between PDFF of CSE-MRI and MRS was calculated to assess accuracy. The SD of Δ and correlation coefficients of the two protocols (standard- and high-SNR) were compared using F-test and t-test, respectively. Two reconstruction algorithms (complex-based and magnitude-based) were used for both the phantom and in vivo experiments.Results: The phantom study demonstrated that higher SNR improved the repeatability for both complex- and magnitude-based reconstruction. Similarly, the in vivo study demonstrated that the repeatability of the high-SNR protocol (SD of Δ = 0.53 for complex- and = 0.85 for magnitude-based fit) was significantly higher than using the standard-SNR protocol (0.77 for complex, P < 0.001; and 0.94 for magnitude-based fit, P = 0.003). No significant difference was observed in the accuracy between standard- and high-SNR protocols.Conclusion: Higher SNR improves the repeatability of fat quantification using confounder-corrected CSE-MRI.
著者
Yoshimitsu OHGIYA Hiroshi NOBUSAWA Noritaka SEINO Osamu MIYAGAMI Naomi YAGI Sasamori HIROTO Jiro MUNECHIKA Masanori HIROSE Nobuyuki TAKEYAMA Nobuyuki OHIKE Ryu MATSUOKA Akihiko SEKIZAWA Takehiko GOKAN
出版者
日本磁気共鳴医学会
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
vol.15, no.2, pp.212-219, 2016 (Released:2016-04-11)
参考文献数
23
被引用文献数
15

Purpose: To evaluate morphological and signal intensity (SI) changes of placental insufficiency on magnetic resonance imaging (MRI) and to assess morphological changes and decreased flow voids (FVs) on T2-weighted rapid acquisition with relaxation enhancement (RARE) images for diagnosing placental insufficiency.Methods: Fifty singleton fetuses underwent MRI using a 1.5-T MR scanner. Placental thickness, area, volume, SI, amniotic fluid SI, and size of FVs between the uterus and the placenta were measured on MR images. Two radiologists reviewed T2-weighted RARE images for globular appearance of the placenta and FVs between the uterus and the placenta. Data were analyzed using t-tests, McNemar’s tests, and areas under the receiver operating characteristic curve (AUCs) at 5% level of significance.Results: Twenty-five of the 50 pregnancies were categorized as having an insufficient placenta. Significant differences were observed between insufficient and normal placentas in mean placental thickness, area, volume, placenta to amniotic fluid SI ratio, and size of FVs (49.0 mm vs. 36.9 mm, 1.62 × 104 mm2 vs. 2.67 × 104 mm2, 5.13 × 105 mm3 vs. 6.56 × 105 mm3, 0.549 vs. 0.685, and 3.4 mm vs. 4.3 mm, respectively). The sensitivity and accuracy using globular appearance plus decreased FVs were greater than those using decreased FVs (P < 0.01). There was no significant difference among AUCs using globular appearance and decreased FVs, and globular appearance plus decreased FVs.Conclusions: Placental insufficiency was associated with placental thickness, area, volume, placenta to amniotic fluid SI ratio, and size of FVs. Evaluating FVs on T2-weighted RARE images can be useful for detecting placental insufficiency, particularly in placentas without globular appearance on MR images.
著者
Kang CHENG
出版者
日本磁気共鳴医学会
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
vol.15, no.1, pp.1-10, 2016-01-01 (Released:2016-01-12)
参考文献数
48
被引用文献数
1 3

This article reviews our exploration of structures and functions of the human visual cortex using high resolution (submillimeter) functional magnetic resonance imaging (fMRI). It discusses factors that restrict the spatial resolution of blood oxygenation-level dependent (BOLD) fMRI–the point-spread function of the BOLD signal, limited by both imaging techniques to be used and neurovascular units to be studied, and the signal-to-noise ratio. I offer personal thoughts regarding optimal solutions for dealing with these issues, summarize techniques we have developed over the years for using high resolution fMRI to visualize functional architectures and explore physiological properties in the primary visual cortex of humans, including choices of imaging hardware and pulse sequences, experimental procedures, and stimulation paradigms, and finally offer my personal opinions regarding the future of high resolution fMRI.
著者
Tomoyuki NOGUCHI Takashi YOSHIURA Akio HIWATASHI Osamu TOGAO Koji YAMASHITA Kouji KOBAYASHI Futoshi MIHARA Hiroshi HONDA
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
vol.6, no.2, pp.91-97, 2007 (Released:2007-08-07)
参考文献数
19
被引用文献数
17 22

Purpose: Pulsed arterial spin labeling (PASL) is a magnetic resonance (MR) method for measuring cerebral blood flow. Although several validation studies for PASL in animals and humans have been reported, no reports have detailed the fundamental study of PASL using a flow phantom. We compared the true and theoretical flow rates in a flow phantom to confirm the analytical validity of quantitative perfusion imaging with Q2TIPS sequence. Methods: We built a flow phantom consisting of a 40-mm diameter plastic syringe filled with plastic beads and small plastic tubes 4 mm in diameter. Gd-DTPA-doped 8L water solution (0.1 mM) was circulated between the syringe and a tank through a plastic tube by a constant flow pump while the flow rate was adjusted between 0 and 2.61 cm/s. Q2TIPS sequence parameters were TI1=50 ms and TI2=1400 ms. Five imaging slices of 50 subtraction images were acquired sequentially in a distal-to-proximal direction using a single-shot echo planar imaging (EPI) technique. The theoretical flow rate calculated based upon the previously reported kinetic model for Q2TIPS was compared with the true flow rate. Results: A good linear relationship was observed between the theoretical, F′, and true flow rates, F, in a flow rate range of 1.43 to 1.95 cm/s (F′=1.024•F−1.915, R2=0.902). The ratio of theoretical to true flow rate was 92 (+/−) 4%. Conclusion: Flow rate was quantified with reasonable accuracy when the entire amount of labeled bolus within the phantom could be recovered. Our experiment confirmed the analytical validity of Q2TIPS and suggested that blood flow measurement may be feasible using the Q2TIPS pulse sequence and kinetic model of the PASL equation.
著者
Yutaka Kato Shinji Naganawa Toshiaki Taoka Tadao Yoshida Michihiko Sone
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2022-0017, (Released:2022-05-10)
参考文献数
16
被引用文献数
1 3

Purpose: To determine whether T2-contrast enhancement techniques can be used to diagnose endolymphatic hydrops, we compared fluid signal artifacts with and without T2-contrast enhancement techniques in 3D fluid-attenuated inversion recovery (3D-FLAIR).Methods: We prepared a custom-made phantom consisting of eight tubes half-filled with saline. Images were obtained using four 3D-FLAIR: without T2-contrast enhancement (Normal), with non-selective T2-inversion recovery (T2-IR), and two with non-selective T2 preparation IR (T2-prep). Scans were performed with and without rice covering the phantom to simulate minimal and severe B0-inhomogeneity conditions. The average signal intensity (SI) values of eight saline tubes were compared between the four sequences and between each other. Comparisons were performed for all measurement slices and the central 10 slices. The images using T2-contrast enhancement technique were obtained from a volunteer and a patient suspected of Meniere’s disease.Results: The Normal sequence SI for all slices was significantly lower than that for the other sequences, with smaller standard deviation (SD) and no outliers. Several outliers were detected in the other sequences. The SDs and outliers were larger without rice than with rice. When the central 10 slices with rice, the T2-IR had a significantly higher SI with more outliers compared with the Normal sequence. The T2-prep had no outliers and SIs that were comparable to those of the Normal sequence. However, without rice, the T2-IR and T2-prep sequences had significantly higher SIs with outliers and larger SDs compared to the Normal sequence. In the corresponding images, the Normal sequence achieved excellent fluid suppression, whereas the T2-IR and T2-prep sequences showed high-signal artifacts. Imperfect fluid suppressions were observed in the volunteer image and the endolymphatic hydrops on the post-gadolinium image differed in size and shape in the non-injected T2-IR in the patient image.Conclusion: T2-contrast enhancement techniques should be used with caution in 3D-FLAIR for diagnosing endolymphatic hydrops.
著者
Hitomi Numamoto Koji Fujimoto Kanae Kawai Miyake Yasutaka Fushimi Sachi Okuchi Rimika Imai Hiroki Kondo Tsuneo Saga Yuji Nakamoto
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2023-0102, (Released:2023-11-10)
参考文献数
20
被引用文献数
1

Purpose: To compare image distortion and reproducibility of quantitative values between reverse encoding distortion correction (RDC) diffusion-weighted imaging (DWI) and conventional DWI techniques in a phantom study and in healthy volunteers.Methods: This prospective study was conducted with the approval of our institutional review board. Written informed consent was obtained from each participant. RDC-DWIs were created from images obtained at 3T in three orthogonal directions in a phantom and in 10 participants (mean age, 70.9 years; age range, 63–83 years). Images without distortion correction (noDC-DWI) and those corrected with B0 (B0c-DWI) were also created. To evaluate distortion, coefficients of variation were calculated for each voxel and ROIs were placed at four levels of the brain. To evaluate the reproducibility of apparent diffusion coefficient (ADC) measurements, intra- and inter-scan variability (%CVADC) were calculated from repeated scans of the phantom. Analysis was performed using Wilcoxon signed-rank test with Bonferroni correction, and P < 0.05 was considered statistically significant.Results: In the phantom, distortion was less in RDC-DWI than in B0c-DWI (P < 0.006), and was less in B0c-DWI than in noDC-DWI (P < 0.006). Intra-scan %CVADC was within 1.30%, and inter-scan %CVADC was within 2.99%. In the volunteers, distortion was less in RDC-DWI than in B0c-DWI in three of four locations (P < 0.006), and was less in B0c-DWI than in noDC-DWI (P < 0.006). At the middle cerebellar peduncle, distortion was less in RDC-DWI than in noDC-DWI (P < 0.006), and was less in noDC-DWI than in B0c-DWI (P < 0.0177).Conclusion: In both the phantom and in volunteers, distortion was the least in RDC-DWI than in B0c-DWI and noDC-DWI.
著者
Atsushi Nakamoto Hiromitsu Onishi Takahiro Tsuboyama Hideyuki Fukui Takashi Ota Keigo Yano Kengo Kiso Toru Honda Hiroyuki Tarewaki Yoshihiro Koyama Mitsuaki Tatsumi Noriyuki Tomiyama
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2023-0039, (Released:2023-10-28)
参考文献数
25

Purpose: To compare objective and subjective image quality, lesion conspicuity, and apparent diffusion coefficient (ADC) of high-resolution multiplexed sensitivity-encoding diffusion-weighted imaging (MUSE-DWI) with conventional DWI (c-DWI) and reduced FOV DWI (rFOV-DWI) in prostate MRI.Methods: Forty-seven patients who underwent prostate MRI, including c-DWI, rFOV-DWI, and MUSE-DWI, were retrospectively evaluated. SNR and ADC of normal prostate tissue and contrast-to-noise ratio (CNR) and ADC of prostate cancer (PCa) were measured and compared between the three sequences. Image quality and lesion conspicuity were independently graded by two radiologists using a 5-point scale and compared between the three sequences.Results: The SNR of normal prostate tissue was significantly higher with rFOV-DWI than with the other two DWI techniques (P ≤ 0.01). The CNR of the PCa was significantly higher with rFOV-DWI than with MUSE-DWI (P < 0.05). The ADC of normal prostate tissue measured by rFOV-DWI was lower than that measured by MUSE-DWI and c-DWI (P < 0.01), while there was no difference in the ADC of cancers. In the qualitative analysis, MUSE-DWI showed significantly higher scores than rFOV-DWI and c-DWI for visibility of anatomy and overall image quality in both readers, and significantly higher scores for distortion in one of the two readers (P < 0.001). There was no difference in lesion conspicuity between the three sequences.Conclusion: High-resolution MUSE-DWI showed higher image quality and reduced distortion compared to c-DWI, while maintaining a wide FOV and similar ADC quantification, although no difference in lesion conspicuity was observed.
著者
Yoshitaka Bito Hisaaki Ochi Ryuji Shirase Wataru Yokohama Kuniaki Harada Kohsuke Kudo
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2023-0081, (Released:2023-10-27)
参考文献数
33

Purpose: Analysis of cerebrospinal fluid (CSF) dynamics may be beneficial for understanding the mechanisms and diagnosis of several neurological diseases. Low b-value diffusion tensor imaging (low-b DTI) is useful for observing the slow and complex motion of the CSF. Theoretically, a mathematical framework suggests that low-b DTI provides the variance of the pseudorandom motion of the CSF. Furthermore, low-b DTI could provide comprehensive information on fluid dynamics. Accordingly, we proposed an analysis technique that resolves intravoxel pseudorandom motion into ordered (linear) and disordered (random) motions based on the mathematical framework.Methods: The proposed analysis technique helps measure low-b DTI with multiple diffusion times and linearly fits its mean diffusivity (MD) with the diffusion time to obtain two parameters, double-slope Vv and y-intersect Dr, which represent the variance of the velocity distribution of linear motion and the diffusion coefficient of random motion, respectively. Seven healthy subjects were scanned to evaluate the proposed technique and investigate fluid dynamics in several representative ROIs.Results: The obtained data showed the validity of the technique, repeatability, and consistency across the subjects in ROIs, such as the lateral ventricle (LV), third ventricle (3V), fourth ventricle (4V), and Sylvian fissure (SF). The obtained parameters Vv and Dr highlighted different characteristics of fluid dynamics in the representative ROIs: low Vv and low Dr in the LV, high Vv and moderate Dr in the 3V, and moderate Vv and moderate Dr in the 4V and SF.Conclusion: The proposed analysis technique will facilitate a comprehensive investigation of the complex dynamics of the CSF using resolved parameters representing ordered and disordered motions.
著者
Hiroyuki MORISAKA Utaroh MOTOSUGI Tomoaki ICHIKAWA Katsuhiro SANO Shintaro ICHIKAWA Tsutomu ARAKI Nobuyuki ENOMOTO
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
vol.12, no.2, pp.77-86, 2013 (Released:2013-06-25)
参考文献数
36
被引用文献数
17 17

Objectives: We evaluated flow parameters measured by phase-contrast magnetic resonance (MR) imaging (PC-MRI) of the portal venous system and liver stiffness measured by MR elastography (MRE) to determine the usefulness of these methods in predicting gastroesophageal varices (GEV) in patients with chronic liver disease (CLD). Methods: In patients with CLD and controls, we performed PC-MRI on the portal (PV) and superior mesenteric veins; calculated mean velocity (V, cm/s), cross-sectional area (S, mm2), and flow volume (Q, mL/min); and determined markers of liver fibrosis (liver stiffness [kPa]) and aspartate aminotransferase (AST) platelet ratio index [APRI]). We visually assessed GEV and development of collateral pathways of the PV on routine contrast-enhanced dynamic MR imaging and compared patient characteristics, flow parameters, liver stiffness markers, and visual analysis among 3GEV groups, those with mild, severe, or no GEV with reference to endoscopic findings. Results: Child-Pugh grade, VPV, SPV, liver stiffness, APRI, and visually identified GEV (visible GEV) differed significantly among the 3 groups (P<0.05). We investigated VPV, SPV, liver stiffness, and visible GEV as independent markers to distinguish patients with and without GEV and examined VPV and visible GEV to predict severe GEV. Visible GEV showed low sensitivity (14 to 30%) and high specificity (98%) for predicting GEV in patients with CLD. A subgroup analysis that excluded cases with collateral pathway demonstrated slightly improved diagnostic performance of VPV and liver stiffness. Conclusions: Portal vein flow parameters and liver stiffness can be useful markers for predicting GEV in patients with CLD.
著者
Masafumi Takafuji Masaki Ishida Satoshi Nakamura Kei Nakata Haruno Ito Takanori Kokawa Kensuke Domae Suguru Araki Shiro Nakamori Junko Ishiura Kaoru Dohi Hajime Sakuma
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2023-0018, (Released:2023-09-28)
参考文献数
37

Purpose: The purposes of this study were to compare global coronary flow reserve (CFR) between patients with idiopathic dilated cardiomyopathy (DCM) and risk-matched controls using cardiac MRI (CMR), and to evaluate the relationship between global CFR and CMR left ventricular (LV) parameters.Methods: Twenty-six patients with DCM and 26 risk-matched controls who underwent comprehensive CMR examination, including stress-rest coronary sinus flow measurement by phase contrast (PC) cine CMR were retrospectively studied. LV peak global longitudinal, radial, and circumferential strains (GLS, GRS, and GCS) were determined by feature tracking.Results: Patients with DCM had significantly lower global CFR compared with the risk-matched controls (2.87 ± 0.86 vs. 4.03 ± 1.47, P = 0.001). Among the parameters, univariate linear regression analyses revealed significant correlation of global CFR with LV end-diastolic volume index (r = –0.396, P = 0.045), LV mass index (r = –0.461, P = 0.018), GLS (r = –0.558, P = 0.003), and GRS (r = 0.392, P = 0.047). Multiple linear regression analysis revealed GLS as the only independent predictor of global CFR (standardized β = –0.558, P = 0.003).Conclusion: Global CFR was significantly impaired in patients with idiopathic DCM and independently associated with LV GLS, suggesting that microvascular dysfunction may contribute to deterioration of LV function in patients with idiopathic DCM.
著者
Kumiko KIKUKAWA Kazuhiro KITAJIMA Tetsuo MAEDA Yoshiko UENO Satoru TAKAHASHI Yoshiharu OHNO Shigeki YOSHIDA Hideto YAMADA Fumi KAWAKAMI Kazuro SUGIMURA
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
vol.11, no.1, pp.71-74, 2012 (Released:2012-03-26)
参考文献数
12
被引用文献数
2 2

Microscopically, ovarian malignant Brenner tumor shows components of malignant transitional cell tumor intermixed with benign and borderline elements. We report a case of this tumor with components that transition from benign to malignant on diffusion-weighted images (DWI) and in histologic findings. The benign component showed low signal intensity on T2-weighted images, whereas the malignant component showed high signal intensity on T2-weighted images and high signal intensity on DWI with low apparent diffusion coefficient (ADC) value.
著者
Hironaka IGARASHI Yuji SUZUKI Vincent J. HUBER Masahiro IDA Tsutomu NAKADA
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
vol.14, no.1, pp.13-24, 2015-02-01 (Released:2015-02-20)
参考文献数
93
被引用文献数
15 23

N-acetylaspartate (NAA) appears in a prominent peak in proton magnetic resonance spectroscopy (1H-MRS) of the brain. Exhibition by NAA of time-dependent attenuation that reflects energy metabolism during the acute stage of cerebral ischemia makes this metabolite a unique biomarker for assessing ischemic stroke. Although magnetic resonance (MR) imaging is a powerful technique for inspecting the pathological changes that occur during ischemic stroke, biomarkers that directly reflect the drastic metabolic changes associated with acute-stage ischemia are strongly warranted for appropriate therapeutic decision-making in daily clinical settings. In this review, we provide a brief overview of NAA metabolism and focus on the use of attenuation in NAA as a means for assessing the pathophysiological changes that occur during the acute stage of ischemic stroke.
著者
Ryoichi Kose Katsumi Kose Koji Fujimoto Tomohisa Okada Daiki Tamada Utaroh Motosugi
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.tn.2023-0063, (Released:2023-09-09)
参考文献数
24
被引用文献数
1

Recent high-performance gradient coils are fabricated mainly at the expense of spatial linearity. In this study, we measured the spatial nonlinearity of the magnetic field generated by the gradient coils of two MRI systems with high-performance gradient coils. The nonlinearity of the gradient fields was measured using 3D gradient echo sequences and a spherical phantom with a built-in lattice structure. The spatial variation of the gradient field was approximated to the 3rd order polynomials. The coefficients of the polynomials were calculated using the steepest descent method. The geometric distortion of the acquired 3D MR images was corrected using the polynomials and compared with the 3D images corrected using the harmonic functions provided by the MRI venders. As a result, it was found that the nonlinearity correction formulae provided by the vendors were insufficient and needed to be verified or corrected using a geometric phantom such as used in this study.
著者
Yuta Endo Sanae Takahashi Haruna Shibo Makoto Amanuma Kuninori Kobayashi Shigehide Kuhara
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2023-0029, (Released:2023-09-04)
参考文献数
26

Purpose: Polarity-corrected inversion time preparation (PCTIP), a myocardial T1 mapping technique, is expected to reduce measurement underestimation in the modified Look-Locker inversion recover method. However, measurement precision is reduced, especially for heart rate variability. We devised an analysis using a recurrence formula to overcome this problem and showed that it improved the measurement accuracy, especially at high heart rates. Therefore, this study aimed to determine the effect of this analysis on the accuracy and precision of T1 measurements for irregular heart rate variability.Methods: A PCTIP scan using a 3T MRI scanner was performed in phantom experiment. We generated the simulated R-waves required for electrocardiogram (ECG)-gated acquisition using a signal generator set to 30 combinations. T1 map was generated using the signal train of the PCTIP images by nonlinear curve fitting using conventional and recurrence formulas. Accuracy against reference T1 and precision of heart rate variability were evaluated. To evaluate the fitting accuracy of both analyses, the relative fitting error was calculated.Results: For the longer T1, the fitting error was larger than the short T1, with the conventional analysis showing 10.1±2.0%. The recurrence formula analysis showed a small fitting error less than 1%, which was consistent for all heart rate variability patterns. In the conventional analysis, the accuracy, especially for longer T1, showed a large underestimation of the measurements and poor linearity. However, in the recurrence formula analysis, the accuracy improved at a long T1, and linearity also improved. The Bland–Altman plot showed that it varied greatly depending on the heart rate variability pattern for the longer T1 in the conventional analysis, whereas the recurrence formula analysis suppressed this variation.Conclusion: T1 analysis of PCTIP using the recurrence formula analysis achieved accurate and precise T1 measurements, even for irregular heart rate variability.
著者
Daisuke Takenaka Yoshiyuki Ozawa Kaori Yamamoto Maiko Shinohara Masato Ikedo Masao Yui Yuka Oshima Nayu Hamabuchi Hiroyuki Nagata Takahiro Ueda Hirotaka Ikeda Akiyoshi Iwase Takeshi Yoshikawa Hiroshi Toyama Yoshiharu Ohno
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2023-0068, (Released:2023-09-01)
参考文献数
36

Purpose: Deep learning reconstruction (DLR) has been recommended as useful for improving image quality. Moreover, compressed sensing (CS) or DLR has been proposed as useful for improving temporal resolution and image quality on MR sequences in different body fields. However, there have been no reports regarding the utility of DLR for image quality and T-factor assessment improvements on T2-weighted imaging (T2WI), short inversion time (TI) inversion recovery (STIR) imaging, and unenhanced- and contrast-enhanced (CE) 3D fast spoiled gradient echo (GRE) imaging with and without CS in comparison with thin-section multidetector-row CT (MDCT) for non-small cell lung cancer (NSCLC) patients. The purpose of this study was to determine the utility of DLR for improving image quality and the appropriate sequence for T-category assessment for NSCLC patients.Methods: As subjects for this study, 213 pathologically diagnosed NSCLC patients who underwent thin-section MDCT and MR imaging as well as T-factor diagnosis were retrospectively enrolled. SNR of each tumor was calculated and compared by paired t-test for each sequence with and without DLR. T-factor for each patient was assessed with thin-section MDCT and all MR sequences, and the accuracy for T-factor diagnosis was compared among all sequences and thin-section CT by means of McNemar’s test.Results: SNRs of T2WI, STIR imaging, unenhanced thin-section Quick 3D imaging, and CE-thin-section Quick 3D imaging with DLR were significantly higher than SNRs of those without DLR (P < 0.05). Diagnostic accuracy of STIR imaging and CE-thick- or thin-section Quick 3D imaging was significantly higher than that of thin-section CT, T2WI, and unenhanced thick- or thin-section Quick 3D imaging (P < 0.05).Conclusion: DLR is thus considered useful for image quality improvement on MR imaging. STIR imaging and CE-Quick 3D imaging with or without CS were validated as appropriate MR sequences for T-factor evaluation in NSCLC patients.