著者
Mayumi TAKEUCHI Kenji MATSUZAKI Yoshimi BANDO Mika SAKAKI Hiroyuki FURUMOTO Masafumi HARADA
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
vol.13, no.4, pp.267-270, 2014-12-01 (Released:2014-12-22)
参考文献数
12
被引用文献数
2 3

Villoglandular papillary adenocarcinoma (VGPA) is a rare subtype of cervical adenocarcinoma that generally affects young women and has a favorable prognosis. Its preoperative diagnosis is important to avoid excessive surgery. We report the magnetic resonance (MR) findings of a case in which the cervical tumor showed a fern-leaf-like appearance on high resolution T2-weighted images obtained at 3 tesla. MR imaging clearly showed this pathological feature that may suggest this disease.
著者
Shinji Naganawa Toshiaki Taoka
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.rev.2020-0122, (Released:2020-11-27)
参考文献数
101
被引用文献数
39

The central nervous system (CNS) was previously thought to be the only organ system lacking lymphatic vessels to remove waste products from the interstitial space. Recently, based on the results from animal experiments, the glymphatic system was hypothesized. In this hypothesis, cerebrospinal fluid (CSF) enters the periarterial spaces, enters the interstitial space of the brain parenchyma via aquaporin-4 (AQP4) channels in the astrocyte end feet, and then exits through the perivenous space, thereby clearing waste products. From the perivenous space, the interstitial fluid drains into the subarachnoid space and meningeal lymphatics of the parasagittal dura. It has been reported that the glymphatic system is particularly active during sleep. Impairment of glymphatic system function might be a cause of various neurodegenerative diseases such as Alzheimer’s disease, normal pressure hydrocephalus, glaucoma, and others. Meningeal lymphatics regulate immunity in the CNS. Many researchers have attempted to visualize the function and structure of the glymphatic system and meningeal lymphatics in vivo using MR imaging. In this review, we aim to summarize these in vivo MR imaging studies and discuss the significance, current limitations, and future directions. We also discuss the significance of the perivenous cyst formation along the superior sagittal sinus, which is recently discovered in the downstream of the glymphatic system.
著者
Enrico Tedeschi Sirio Cocozza Pasquale Borrelli Lorenzo Ugga Vincenzo Brescia Morra Giuseppe Palma
出版者
日本磁気共鳴医学会
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.cr.2016-0137, (Released:2017-03-27)
参考文献数
24
被引用文献数
9

We report the assessment of Dentate Nuclei (DN) R1 (1/T1) and R2* (1/R2*) values in a patient with relapsing-remitting Multiple Sclerosis, exposed to 22 standard (0.1 mmol/kg) doses of gadobutrol, who underwent eight relaxometric magnetic resonance (MR) measurements within two years. DN R1 did not significantly increase nor correlated with cumulative gadobutrol administration, even after a total dose of 130 ml. Likewise, DN R2* relaxometry remained unchanged. In conclusion, massive gadobutrol exposure did not induce significant DN relaxometry changes.
著者
Shinji Naganawa Toshiki Nakane Hisashi Kawai Toshiaki Taoka Hirokazu Kawaguchi Katsuya Maruyama Katsutoshi Murata Gregor Körzdörfer Josef Pfeuffer Mathias Nittka Michihiko Sone
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2019-0048, (Released:2019-06-20)
参考文献数
31
被引用文献数
14

Purpose: It has been reported that leakage of intravenously administered gadolinium-based contrast agents (IV-GBCAs) into the cerebrospinal fluid (CSF) from the cortical veins even in healthy subjects can be detected using a highly sensitive pulse sequence such as heavily T2-weighted 3D fluid-attenuated inversion recovery and 3D-real inversion recovery (IR). The purpose of this study was to evaluate the feasibility of MR fingerprinting to detect GBCA leakage from the cortical veins after IV-GBCA.Materials: Fourteen patients with suspected endolymphatic hydrops (EH) who received a single dose of IV-GBCA (39–79 years old) were included. The real IR images as well as MR fingerprinting images were obtained at 4 h after IV-GBCA. T1 and T2 values were obtained using MR fingerprinting and analyzed in ROIs covering intense GBCA leakage, and non-leakage areas of the CSF as determined on real IR images. The scan time for real IR imaging was 10 min and that for MR fingerprinting was 41 s.Results: The mean T1 value of the ROI in the area of GBCA leakage was 2422 ± 261 ms and that in the non-leakage area was 3851 ± 235 ms (P < 0.01). There was no overlap between the T1 values in the area of GBCA leakage and those in the non-leakage area.The mean T2 value in the area of GBCA leakage was 319 ± 90 ms and that in the non-leakage area was 670 ± 166 ms (P < 0.01). There was some overlap between the T2 values in the area of GBCA leakage and those in the non-leakage area.Conclusion: Leaked GBCA from the cortical veins into the surrounding CSF can be detected using MR fingerprinting obtained in <1 min.
著者
Shigeyoshi Soga Taro Koyama Ayako Mikoshi Tatsuhiko Arafune Makoto Kawashima Kazuhiro Kobayashi Hiroshi Shinmoto
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
vol.20, no.2, pp.160-165, 2021 (Released:2021-06-01)
参考文献数
14
被引用文献数
2

Purpose: Although androgenetic alopecia (AGA) is a common cause of hair loss, little is known regarding the magnetic resonance imaging (MRI) of the AGA or scalp. This study aimed to analyze whether MRI for hair and scalp (MRH) can evaluate anatomical changes in the scalp caused by AGA.Methods: Twenty-seven volunteers were graded for the severity of AGA using the Hamilton–Norwood Scale (HNS), commonly used classification system. All subjects underwent MRH; two radiologists independently analyzed the images. As a quantitative measurement, the number of hair follicles was analyzed and compared with the HNS. As a qualitative analysis, each MRH scan was visually graded in terms of the severity of alopecia, using a 4-point MR severity score. The scores were compared with the HNS.Results: The volunteers were divided into two groups of 12 and 15 males without and with AGA at their vertex, respectively. Inter-observer agreements for the hair count and the MR severity score were excellent. The mean hair count on MRI in the normal group was significantly higher than that in the AGA group (P < 10−4). The MR severity score in the AGA group was significantly more severe than that in the control group (P < 10−4). In terms of the presence or absence of thinning hair, the MR severity score was consistent with the HNS determined by a plastic surgeon in 96% of cases. MR severity scores of clinically moderate AGA cases were significantly lower than those of severe cases (P = 0.022).Conclusion: MRH could depict scalp anatomy showing a clear difference between AGA and normal scalps, in both hair count and subjective visual assessment. The MR severity score was in good agreement with the clinical stages by HNS. The results support the potential of MRH as a promising imaging technique for analyzing healthy and pathological scalps.
著者
Zbyněk Tüdös Martin Köcher Marie Černá František Odstrčil Zuzana Prouzová Radim Formánek Jan Přeček
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
vol.16, no.2, pp.176-180, 2017 (Released:2017-04-10)
参考文献数
12
被引用文献数
9 9

Our article reports a case of a 35-year-old man with cardiac mass, who underwent a wide range of imaging methods, including cardiac magnetic resonance imaging (MRI) and positron emission tomography/computed tomography (PET/CT). Contrast-enhanced MRI images revealed “sun ray” pattern in the mass. Final histopathological diagnosis of angiosarcoma was confirmed during autopsy. To our knowledge, our case is the second direct observation of this MRI diagnostic pattern and the first one that allows a comparison with PET/CT findings.
著者
Moyoko Tomiyasu Masafumi Harada
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
vol.21, no.1, pp.235-252, 2022 (Released:2022-03-01)
参考文献数
201
被引用文献数
1 7

MR spectroscopy (MRS) is a unique and useful method for noninvasively evaluating biochemical metabolism in human organs and tissues, but its clinical dissemination has been slow and often limited to specialized institutions or hospitals with experts in MRS technology. The number of 3-T clinical MR scanners is now increasing, representing a major opportunity to promote the use of clinical MRS. In this review, we summarize the theoretical background and basic knowledge required to understand the results obtained with MRS and introduce the general consensus on the clinical utility of proton MRS in routine clinical practice. In addition, we present updates to the consensus guidelines on proton MRS published by the members of a working committee of the Japan Society of Magnetic Resonance in Medicine in 2013. Recent research into multinuclear MRS equipped in clinical MR scanners is explained with an eye toward future development. This article seeks to provide an overview of the current status of clinical MRS and to promote the understanding of when it can be useful. In the coming years, MRS-mediated biochemical evaluation is expected to become available for even routine clinical practice.
著者
Maya Honda Mami Iima Masako Kataoka Yasuhiro Fukushima Rie Ota Akane Ohashi Masakazu Toi Yuji Nakamoto
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2022-0060, (Released:2022-08-03)
参考文献数
35
被引用文献数
2

Purpose: To investigate whether intravoxel incoherent motion (IVIM) and/or non-Gaussian diffusion parameters are associated with distant disease-free survival (DDFS) in patients with invasive breast cancer.Methods: From May 2013 to March 2015, 101 patients (mean age 60.0, range 28–88) with invasive breast cancer were evaluated prospectively. IVIM parameters (flowing blood volume fraction [fIVIM] and pseudodiffusion coefficient [D*]) and non-Gaussian diffusion parameters (theoretical apparent diffusion coefficient [ADC] at a b value of 0 s/mm2 [ADC0] and kurtosis [K]) were estimated using a diffusion-weighted imaging series of 16 b values up to 2500 s/mm2. Shifted ADC values (sADC200–1500) and standard ADC values (ADC0–800) were also calculated. The Kaplan–Meier method was used to generate survival analyses for DDFS, which were compared using the log-rank test. Univariable Cox proportional hazards models were used to assess any associations between each parameter and distant metastasis-free survival.Results: The median observation period was 80 months (range, 35–92 months). Among the 101 patients, 12 (11.9%) developed distant metastasis, with a median time to metastasis of 79 months (range, 10–92 months). Kaplan–Meier analysis showed that DDFS was significantly shorter in patients with K > 0.98 than in those with K ≤ 0.98 (P = 0.04). Cox regression analysis showed a marginal statistical association between K and distant metastasis-free survival (P = 0.05).Conclusion: Non-Gaussian diffusion may be associated with prognosis in invasive breast cancer. A higher K may be a marker to help identify patients at an elevated risk of distant metastasis, which could guide subsequent treatment.
著者
Seiya Kishi Masayuki Maeda Fumine Tanaka Ryota Kogue Maki Umino Hajime Sakuma
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.bc.2022-0120, (Released:2023-01-24)
参考文献数
10

We observed a new SWI finding, “cortical brush sign,” that represents prominent venous structures in the cortex of patients with acute cerebral infarct with or without moyamoya disease and cerebral venous thrombosis. The cortical brush sign disappeared on follow-up SWI in all cases. Cortical brush sign may help to understand the pathophysiology of venous structures in the cortex at acute phase.
著者
Mika Kitajima Hiroyuki Uetani
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.rev.2021-0118, (Released:2022-03-23)
参考文献数
84
被引用文献数
7

Dynamic susceptibility contrast (DSC) and arterial spin labeling (ASL) are techniques used to evaluate brain perfusion using MRI. DSC requires dynamic image acquisition with a rapid administration of gadolinium-based contrast agent. In contrast, ASL obtains brain perfusion information using magnetically labeled blood water as an endogenous tracer. For the evaluation of brain perfusion in pediatric neurological diseases, ASL has a significant advantage compared to DSC, CT, and single-photon emission CT/positron emission tomography because of the lack of radiation exposure and contrast agent administration. However, in ASL, optimization of several parameters, including the type of labeling, image acquisition, background suppression, and postlabeling delay, is required, because they have a significant effect on the quantification of cerebral blood flow (CBF).In this article, we first review recent technical developments of ASL and age-dependent physiological characteristics in pediatric brain perfusion. We then review the clinical implementation of ASL in pediatric neurological diseases, including vascular diseases, brain tumors, acute encephalopathy with biphasic seizure and late reduced diffusion (AESD), and migraine. In moyamoya disease, ASL can be used for brain perfusion and vessel assessment in pre- and post-treatment. In arteriovenous malformations, ASL is sensitive to detect small degrees of shunt. Furthermore, in vascular diseases, the implementation of ASL-based time-resolved MR angiography is described. In neoplasms, ASL-derived CBF has a high diagnostic accuracy for differentiation between low- and high-grade pediatric brain tumors. In AESD and migraine, ASL may allow for accurate early diagnosis and provide pathophysiological information.
著者
Michiru Kajiwara Tomoyuki Haishi Dwi Prananto Susumu Sasaki Ryohei Kaseda Ichiei Narita Yasuhiko Terada
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.tn.2021-0094, (Released:2021-12-10)
参考文献数
19
被引用文献数
1

23Na-MRI provides information on Na+ content, and its application in the medical field has been highly anticipated. However, for existing clinical 1H-MRI systems, its implementation requires an additional broadband RF transmitter, dedicated transceivers, and RF coils for Na+ imaging. However, a standard medical MRI system cannot often be modified to perform 23Na imaging. We have developed an add-on crossband RF repeater system that enables 23Na-MRI simply by inserting it into the magnet bore of an existing 1H MRI. The three axis gradient fields controlled by the 1H-MRI system were directly used for 23Na imaging without any deformation. A crossband repeater is a common technique used for amateur radio. This concept was proven by a saline solution phantom and in vivo mouse experiments. This add-on RF platform is applicable to medical 1H MRI systems and can enhance the application of 23Na-MRI in clinical usage.
著者
Koichi Oshio
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.bc.2021-0059, (Released:2021-10-13)
参考文献数
9
被引用文献数
3

Although the glymphatic system hypothesis is highly popular, it also lacks certain details. In this paper, an attempt was made to present a more clearly defined hypothesis, which is consistent with the past experiment results. The new hypothesis consists of (1) water flux in the brain parenchyma, (2) water and solutes pathway of the perivascular space, and (3) maintenance of this pathway by the network of astrocytes.
著者
Kazuhiro Koyanagawa Yuta Kobayashi Tadao Aikawa Atsuhito Takeda Hideaki Shiraishi Satonori Tsuneta Noriko Oyama-Manabe Hiroyuki Iwano Toshiyuki Nagai Toshihisa Anzai
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.bc.2020-0069, (Released:2020-09-07)
参考文献数
18
被引用文献数
1

To assess myocardial fibrosis associated with muscular dystrophy, T1-mapping and extracellular volume fraction (ECV) quantification was prospectively performed using cardiovascular MR (CMR) imaging in 6 male patients with muscular dystrophy and 5 female putative carriers of Duchenne or Becker muscular dystrophy. Five patients and all putative carriers had an elevated ECV (>29.5% for men and >35.2% for women), suggesting that ECV has a potential to detect diffuse fibrotic changes in patients and putative carriers of muscular dystrophy.
著者
Nobuyasu Ichinose Kentaro Haraoka Takaya Mori Masanori Ozaki Akira Taniguchi
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2023-0074, (Released:2023-11-02)
参考文献数
18

Purpose: Recently, the utility of non-contrast MR endolymphatic hydrops imaging was reported, but the pitfall was indicated based on T2 preparation pulse sensitiveness to local static magnetic field (B0) inhomogeneity. The purpose of this study is to clarify the effects of surrounding magnetic environment of temporal bone to lymphatic fluid signal intensity on the T2 preparation and fluid attenuated inversion recovery pulse combination (T2prep 3D-FLAIR) technique in human inner ear study.Methods: We prepared a custom-made phantom comprising a chicken leg bone submersed in saline. To evaluate signal characteristics of saline close to bone, multiple TE gradient echoes, T2 relaxation time measurement, and T2prep 3D-FLAIR image were acquired. In the vicinity of the vestibule of a healthy volunteer, similar examinations were executed. Additionally, to investigate the influence of the magnetic environment from B0, the evaluation was performed in five head position settings relative to B0.Results: In both the phantom case and volunteer case, together with T2 star signal intensity attenuation, T2 relaxation time shortening was observed on fluid around bone. Specifically, at the outer edge in the vestibule and cochlea of the volunteer, T2 relaxation time was shorter than that of center of vestibule and that of cochlea. In the T2prep 3D-FLAIR image, higher signal intensity was observed at the same location on the outer edge of them. These results showed that bone affects surrounding fluid magnetic environment. Also, for B0 influence, despite a large area variation ratio, there is no statistically significant difference correlated to orientation within B0.Conclusion: The surrounding magnetic environment of the temporal bone affects lymphatic fluid signals of the peripheral part of the human inner ear on T2prep 3D-FLAIR technique.
著者
Masaki Ishida Jérôme Yerly Haruno Ito Masafumi Takafuji Shiro Nakamori Shinichi Takase Yoshito Ichiba Yoshiaki Komori Kaoru Dohi Davide Piccini Jessica A.M. Bastiaansen Matthias Stuber Hajime Sakuma
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.tn.2022-0086, (Released:2023-01-20)
参考文献数
17
被引用文献数
2

Free-running 5D whole-heart coronary MR angiography (MRA) is gaining in popularity because it reduces scanning complexity by removing the need for specific slice orientations, respiratory gating, or cardiac triggering. At 3T, a gradient echo (GRE) sequence is preferred in combination with contrast injection. However, neither the injection scheme of the gadolinium (Gd) contrast medium, the choice of the RF excitation angle, nor the dedicated image reconstruction parameters have been established for 3T GRE free-running 5D whole-heart coronary MRA. In this study, a Gd injection scheme, RF excitation angles of lipid-insensitive binominal off-resonance RF excitation (LIBRE) pulse for valid fat suppression and continuous data acquisition, and compressed-sensing reconstruction regularization parameters were optimized for contrast-enhanced free-running 5D whole-heart coronary MRA using a GRE sequence at 3T. Using this optimized protocol, contrast-enhanced free-running 5D whole-heart coronary MRA using a GRE sequence is feasible with good image quality at 3T.
著者
Shinji Naganawa Rintaro Ito Mariko Kawamura Toshiaki Taoka Tadao Yoshida Michihiko Sone
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2021-0100, (Released:2021-10-16)
参考文献数
18
被引用文献数
6

Purpose: Peripheral retinal leakage (PRL) of contrast medium from the ora serrata (i.e., the peripheral part of the retina) was recently reported in normal eyes using ultra-widefield fluorescein angiography. We occasionally see PRL of gadolinium-based contrast agents (GBCAs) in the vitreous from the temporal and inferior sides of the ora serrata on MR images of subjects without ophthalmic disease. In this study, we retrospectively evaluated these MR images to determine if PRL was associated with aging. We also evaluated whether the initial leakage appeared in the temporal and inferior sides, and whether there was uniform distribution within the vitreous after 24 hours.Methods: In 127 subjects (9 volunteers, 85 patients with sudden deafness, and 33 patients with a suspicion of endolymphatic hydrops), pre- and post-contrast-enhanced heavily T2-weighted 3D-fluid attenuated inversion recovery (FLAIR) images were obtained. The presence or absence of PRL was subjectively evaluated. For patients with a suspicion of endolymphatic hydrops, 3D-real inversion recovery (IR) images were also obtained at pre-, 10 mins, 4 hours, and 24 hours after intravenous administration (IV) of GBCA. Four circular ROIs were placed in the vitreous humor and the signal intensity was measured.Results: In the cases with PRL (n = 88) and without PRL (n = 47), the median age was 59 and 47 years, respectively (P = 0.001). At 4 hours after IV-GBCA, the mean signal increase in the inferior temporal ROI was greater than all the other ROIs. At 24 hours after IV-GBCA, no significant difference in signal intensity was observed for the four ROIs.Conclusion: PRL of GBCA is age-dependent and occurs mainly from the inferior temporal side of the ora serrata. The contrast effect was uniformly distributed at 24 hours after IV-GBCA. Future observations in a variety of diseases will determine the clinical significance of these findings.
著者
Hajime Sakuma Masaki Ishida
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.rev.2021-0033, (Released:2021-06-09)
参考文献数
86
被引用文献数
5

Stress myocardial perfusion imaging (MPI) is the preferred test in patients with intermediate-to-high clinical likelihood of coronary artery disease (CAD) and can be used as a gatekeeper to avoid unnecessary revascularization. Cardiac magnetic resonance (CMR) has a number of favorable characteristics, including: (1) high spatial resolution that can delineate subendocardial ischemia; (2) comprehensive assessment of morphology, global and regional cardiac functions, tissue characterization, and coronary artery stenosis; and (3) no radiation exposure to patients. According to meta-analysis studies, the diagnostic accuracy of perfusion CMR is comparable to positron emission tomography (PET) and perfusion CT, and is better than single-photon emission CT (SPECT) when fractional flow reserve (FFR) is used as a reference standard. In addition, stress CMR has an excellent prognostic value. One meta-analysis study demonstrated the annual event rate of cardiovascular death or non-fatal myocardial infarction was 4.9% and 0.8%, respectively, in patients with positive and negative stress CMR. Quantitative assessment of perfusion CMR not only allows the objective evaluation of regional ischemia but also provides insights into the pathophysiology of microvascular disease and diffuse subclinical atherosclerosis. For accurate quantification of myocardial perfusion, saturation correction of arterial input function is important. There are two major approaches for saturation correction, one is a dual-bolus method and the other is a dual-sequence method. Absolute quantitative mapping with myocardial perfusion CMR has good accuracy in detecting coronary microvascular dysfunction. Flow measurement in the coronary sinus (CS) with phase contrast cine CMR is an alternative approach to quantify global coronary flow reserve (CFR). The measurement of global CFR by quantitative analysis of perfusion CMR or flow measurement in the CS permits assessment of microvascular disease and diffuse subclinical atherosclerosis, which may provide improved prediction of future event risk in patients with suspected or known CAD. Multi-institutional studies to validate the diagnostic and prognostic values of quantitative perfusion CMR approaches are required.
著者
Iichiro Osawa Eito Kozawa Yuya Yamamoto Sayuri Tanaka Taira Shiratori Akane Kaizu Kaiji Inoue Mamoru Niitsu
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2021-0021, (Released:2021-05-13)
参考文献数
25
被引用文献数
2

Purpose: The purpose of the present study was to evaluate contrast enhancement of the infundibular recess in the normal state using heavily T2-weighted 3D fluid-attenuated inversion recovery (FLAIR) (HT2-FLAIR).Methods: Twenty-six patients were retrospectively recruited. We subjectively assessed overall contrast enhancement of the infundibular recess between postcontrast, 4-hour (4-h) delayed postcontrast, and precontrast HT2-FLAIR images. We also objectively conducted chronological and spatial comparisons by measuring the signal intensity (SI) ratio (SIR). Chronological comparisons were performed by comparing SI of the infundibular recess/SI of the midbrain (SIRIR-MB). Spatial comparisons were conducted by comparing SI on postcontrast HT2-FLAIR/SI on precontrast HT2-FLAIR (SIRPost-Pre) of the infundibular recess with that of other cerebrospinal fluid (CSF) spaces, including the superior part of the third ventricle, lateral ventricles, fourth ventricle, and interpeduncular cistern.Results: In the subjective analysis, all cases showed contrast enhancement of the infundibular recess on both postcontrast and 4-h delayed postcontrast HT2-FLAIR, and showed weaker contrast enhancement of the infundibular recess on 4-h delayed postcontrast HT2-FLAIR than on postcontrast HT2-FLAIR. In the objective analysis, SIRIR-MB was the highest on postcontrast images, followed by 4-h delayed postcontrast images. SIRPost-Pre was significantly higher in the infundibular recess than in the other CSF spaces.Conclusion: The present results demonstrated that the infundibular recess was enhanced on HT2-FLAIR after an intravenous gadolinium injection. The infundibular recess may be a potential source of the leakage of intravenously administered gadolinium into the CSF.
著者
Yoshitaka Masutani
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.rev.2021-0005, (Released:2021-05-21)
参考文献数
92
被引用文献数
1

In this paper, fundamentals and recent progress for obtaining biological features quantitatively by using diffusion MRI are reviewed. First, a brief description of diffusion MRI history, application, and development was presented. Then, well-known parametric models including diffusion tensor imaging (DTI), diffusional kurtosis imaging (DKI), and neurite orientation dispersion diffusion imaging (NODDI) are introduced with several classifications in various viewpoints with other modeling schemes. In addition, this review covers mathematical generalization and examples of methodologies for the model parameter inference from conventional fitting to recent machine learning approaches, which is called Q-space learning (QSL). Finally, future perspectives on diffusion MRI parameter inference are discussed with the aspects of imaging modeling and simulation.
著者
Osamu Yanagisawa Tomoki Oshikawa Naoto Matsunaga Gen Adachi Koji Kaneoka
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2020-0052, (Released:2020-09-01)
参考文献数
20
被引用文献数
3

Purpose: We aimed to evaluate the acute physiological effects of high-load deadlift exercise on the lumbar intervertebral discs using MR diffusion-weighted imaging (DWI).Methods: Fifteen volunteers (11 men and 4 women; 23.2 ± 3.3 years) without lumbar intervertebral disc degeneration performed deadlift exercise (70% of 1 repetition maximum, 6 repetitions, 5 sets, 90 s rest between sets) using a Smith machine. Sagittal MR diffusion-weighted images of the lumbar intervertebral discs were obtained using a 1.5-Tesla MR system with a spine coil before and immediately after the exercise. We calculated apparent diffusion coefficient (ADC; an index of water movement) of the nucleus pulposus from diffusion weighted images at all lumbar intervertebral discs (L1/2 through L5/S1).Results: All lumbar intervertebral discs showed significantly decreased ADC values immediately after deadlift exercise (L1/2, −2.8%; L2/3, −2.1%; L3/4, −2.8%; L4/5, −4.9%; L5/S1, −6.2%; P < 0.01). In addition, the rate of ADC decrease of the L5/S1 disc was significantly greater than those of the L1/2 (P = 0.017), L2/3 (P < 0.01), and L3/4 (P = 0.02) discs.Conclusion: The movement of water molecules within the lumbar intervertebral discs is suppressed by high-load deadlift exercise, which would be attributed to mechanical stress on the lumbar intervertebral discs during deadlift exercise. In particular, the L5/S1 disc is subjected to greater mechanical stress than the other lumbar intervertebral discs.