著者
西原 一嘉 Knisely Charles W. 中畑 佑介 井口 学
出版者
日本実験力学会
雑誌
実験力学 (ISSN:13464930)
巻号頁・発行日
vol.8, no.3, pp.189-195, 2008-09-25 (Released:2009-03-25)
参考文献数
37

Experimental Investigation has been carried out on turbulent flow around an obstacle placed on the lower wall of a square duct. Particular emphasis is placed on the velocity distribution of turbulent flow, the reattachment length, and the static pressure distribution on the upper wall of the duct. Two types of obstacles are used: a backward-facing step and a diffuser-like constriction. A flow visualization method is used for measuring the velocity distribution and reattachment length. Soap bubbles are used as the tracer. A pressure transducer is used for measuring the static pressure distribution. A blockage factor is introduced to correlate the static pressure distribution. The reattachment length depends strongly on the shape and size of an obstacle. An empirical equation is proposed for the reattachment length.
著者
西原 一嘉 西原 小百合 安富 雅典 新関 雅俊
出版者
日本図学会
雑誌
図学研究 (ISSN:03875512)
巻号頁・発行日
vol.39, no.Supplement2, pp.31-36, 2005 (Released:2010-08-25)

大阪電気通信大学では現在、工学部1部機械工学科、総合情報学部メディア情報文化学科、短期大学部、工学部2部機械工学科にてAutoCAD LTをもちいたCADによる製図実習、CAD利用技術者検定試験受験の基礎についての演習を行っている。本年度より将来のCAD導入を目指して、設計を主体とする企業でのCADを取り入れた、実線的な演習を行っているので、これについて報告する。
著者
駒井 啓二 富永 晟浩 川村 次郎 松矢 正利 福井 信佳 田中 政敏 西原 一嘉
出版者
バイオメカニズム学会
雑誌
バイオメカニズム (ISSN:13487116)
巻号頁・発行日
vol.8, pp.155-164, 1986-09-25 (Released:2016-12-05)

Using surface electrodes, we have developed and tested clinically FES systems for lower and upper limbs of hemiplegic patients and for upper limbs of quadriplegic patients. Furthermore, we have studied fatigue of muscle contraction caused by FES and intermittent sinusoidal high frequency stimulation. We have developed a peroneal stimulator for hemiplegic patients. Now, we are waiting approval of the Ministry of Welfare before putting it on the market in Japan. Clinical factors of hemiplegia relating to the peroneal stimulator were analyzed in 80 patients. It was found that hemiplegic patients who were slightly spastic and above stage IV of lower limb functional level (Brunnstrom) were good candidates for using the FES. According to our experience. FES was very suitable for the Japanese life style. We also developed a one-channel stimulator for upper limbs of hemiplegic patients. The stimulator was suitable for patients who have hypertonus of finger flexors. We have developed a two-channel stimulator for C_5-level quadriplegic patients. Finger flexors and extensors of only one hand are stimulated through two pairs of surface electrodes by this stimulator. The stimulator is controlled by a toggle switch which is manipulated by the other hand. Although the method of control is on/off in this system, strength of stimulation is increased gradually at the start of so that finger movement is gradual. In order to get active prehension and release by two-channel stimulation, a splint which stabilizes the wrist and thumb in the functional position was used. Furthermore, four fingers, the index finger to small finger, were held together by the finger support. In performance tests with three patients, it has been proven that quadriplegic patients are able to restore grasping by using this stimulator. We have measured muscle fatigue during FES and the period which is required for its cessation. In case of 60-second stimulation, 60-second off time was required for 90% restoration of grasping force. We have studied intermittent sinusoidal high frequency stimulation both in order to increase grasping force and to control pain. It was found that the grasping force by intermittent sinusoidal high-frequency stimulation (5.7kgf) is larger than grasping force by low-frequency stimulation (3.2kgf). However, patients who were stimulated by intermittent sinusoidal high frequency complained of more numbness than those stimulated by low-frequency stimulation.
著者
松村 雅史 中野 剛 西原 一嘉 吉田 正樹
出版者
一般社団法人電子情報通信学会
雑誌
電子情報通信学会技術研究報告. EA, 応用音響
巻号頁・発行日
vol.98, no.231, pp.37-42, 1998-07-31
参考文献数
18

本研究では、バイオリン音生成時の運動パラメータと生成音の音響的性質の関係を調べるために、運弓、弓圧を総合的にコンピュータ制御可能なバイオリン音生成システムを試作した。まず、本システムでは、10-40cm/sの速度で運弓している場合において、2.5gWの精度で弓圧力が制御可能であることを示した。次に、音階制御機構部についての基礎実験として、弦を押さえる荷重と発生音のスペクトルの関連を実験的に調べた。バイオリン音のスペクトルで倍音生分とそれ以外の成分の比mを特徴パラメータとし、弦を押さえる荷重(100-400gW)との関係を測定した。その結果、荷重が小さい場合、mの値は小さく、聴覚的印象も悪いが、荷重を大きくするとmが急激に高くなり、聴覚的印象も良くなる傾向が示された。
著者
西原 一嘉 西原 小百合 安富 雅典 新関 雅俊 大西 道一
出版者
日本図学会
雑誌
図学研究 (ISSN:03875512)
巻号頁・発行日
vol.40, no.Supplement1, pp.171-174, 2006 (Released:2010-08-25)
参考文献数
1

F.Hohenberg (1) が指摘しているように建物を二方向から撮った写真があれば、透視図を逆変換することにより建物の三次元形状を再現することができる。しかし、昔の町並みのように一枚の写真しか残されていない場合はこの方法は使えない。これまで、一枚の写真とともに残されている地図を併用することによって建物を再現する方法を検討してきた。具体的には建物の形状をデジタルカメラで撮影し、その画像から図学的手法を用いて (Auto CADを使用し) 再現するものである。なお、実際の撮影において、隣の建物や木などが邪魔をして建物の地面の位置が隠れてしまうという問題や地図上に基準となる正方形が取れない問題やさらに建物の高さの測定精度がかなり低くなる問題も生じると考えられる。そこで、本研究ではシミュレーションにより、以上の問題点を解決する方法を検討した。
著者
西原 小百合 西原 一嘉 井口 学
出版者
日本実験力学会
雑誌
実験力学 (ISSN:13464930)
巻号頁・発行日
vol.10, no.2, pp.217-223, 2010-06-25 (Released:2010-12-25)
参考文献数
5

Recently, design of cars and household appliances has mainly been carried out using various types of 3-D CAD systems. Although the 3-D CAD is superior for presenting the shape of the object, some problems are left unsolved. For example, it is widely recognized in the mechanical design field that conversion of a 3-D image to 2-D production drawings is not always adequate because the description of the measure is sometimes inaccurate. Under these conditions, correction of the drawings should be carried out one by one. Nevertheless, the use of 3-D CAD is rapidly increasing and, accordingly, educational institutions teaching 3-D CAD are increasing year by year. This paper reports on the introduction of 3-D CAD to descriptive geometry field. The objective of the present study is to improve the above-mentioned shortcoming of 3-D CAD on the measure description. Many kinds of problems encountered in descriptive geometry are solved using 3-D CAD.
著者
尾杉 匡哉 西原 一嘉 北山 一郎 前川 了一 大島 康敬
出版者
一般社団法人電子情報通信学会
雑誌
電子情報通信学会技術研究報告. MBE, MEとバイオサイバネティックス (ISSN:09135685)
巻号頁・発行日
vol.101, no.406, pp.7-12, 2001-11-02
被引用文献数
2

これまでに、開発されている電動義手の大部分がDCモータを使用しているが、モータ稼動時に"ノイズ音"が発生するという問題点がある。そこで、稼動時にノイズ音が少ないという特徴をもつ超音波モータを用いることによって、モータ音の低減を行った。また、これを用いて被験者1名について、日常生活動作による評価を行い、その有効性を確認した。