著者
八木 浩史 北村 怜子 猿渡 理恵 土居 奈津子 山根 英里子
出版者
公益社団法人日本放射線技術学会
雑誌
日本放射線技術學會雜誌 (ISSN:03694305)
巻号頁・発行日
vol.59, no.6, pp.729-736, 2003-06-20
被引用文献数
5

The half-value layer (HVL) of an X-ray beam for film-screen mammography is considered an important parameter for image quality and patient dose. Thus, HVL must be measured in accordance with The Manual of Accuracy for Mammography printed by the Japanese Society of Radiological Technology. The manual prescribes exactly the geometry of measurement, chamber position of measurement in the field, selection of chamber, and so on. However, the measurement of HVL is difficult in the actual clinical setting. This study examined the results of failure to perform the measurement of HVL in accordance with the manual for measuring HVL in the clinical setting. The investigation indicated that serious problems do not arise when measuring HVL for routine quality control even if the chamber in the field is not always set according to the manual and if a chamber for radiotherapy or diagnosis is used that is not recommended for soft X-ray by the manual.
著者
熊谷 孝三 天内 廣 太田原 美郎 西村 健司 森田 立美
出版者
公益社団法人日本放射線技術学会
雑誌
日本放射線技術學會雜誌 (ISSN:03694305)
巻号頁・発行日
vol.60, no.8, pp.1072-1077, 2004-08-20
被引用文献数
2

医療に向けられる社会の評価はかつてなく厳しいものになっており,その厳しさを示す具体的なものとして,医療事故をめぐる紛争,訴訟の増加が挙げられる.また日常の診療においては,患者への危害のみならず,物損や患者からの苦情など病院のイメージダウンを引き起こす要因が潜んでいる.これらも医療事故,紛争に直結するおそれがあり,病院の経済的損失につながる.したがって,自分の職場ではどのようなリスクが存在しているのか,また実際に起こっているかを調査し,その内容を把握することが重要である.これらのことを受け,本報ではアンケート調査を実施し,放射線業務において発生している患者からの苦情・質問についてモダリティ別に事例集としてまとめたので報告する.
著者
栗山 巧 坂井 信幸 新井田 紀光 古川 宗 大西 久美子 三上 朋子 奥町 英世 今村 博敏 坂井 千秋
出版者
Japanese Society of Radiological Technology
雑誌
日本放射線技術學會雜誌 (ISSN:03694305)
巻号頁・発行日
vol.68, no.12, pp.1652-1661, 2012-12-20
参考文献数
23
被引用文献数
1

<i>Purpose</i>: We made the fusion image of both stent and platinum coil after embolization of an unruptured aneurysm. <i>Method</i>: After scanning with cone beam computed tomography, we made three dimensional (3D) images of stent and coil and fused them. <i>Conclusion</i>: We can evaluate unruptured aneurysm after embolization by using a fusion image. 3D-fusion image is useful on clinical cases.
著者
栗山 巧 古川 宗 清水 敬二 大西 久美子 酒井 慎治 今村 博敏 坂井 千秋 坂井 信幸
出版者
Japanese Society of Radiological Technology
雑誌
日本放射線技術學會雜誌 (ISSN:03694305)
巻号頁・発行日
vol.68, no.1, pp.95-102, 2012-01-20
参考文献数
13
被引用文献数
1

We compared the accuracy in evaluating an unrapture aneurysm between NV and 3D-DSA. In vitro, we evaluated the accuracy in calculating the volume of the Aneurysm model. We compared the diameter of the first coil and estimated the diameter of the Aneurysm. The Aneurysm size calculated by NV resembled the first coil more than the size measured by 3D-DSA. In clinical cases, the measurement of NV is objective; the measurement of 3D-DSA, however, is subjective by person. NV has an automatic measurement that is useful for clinical cases.
著者
栗山 巧 坂井 信幸 古川 宗 大西 久美子 奥町 英世 今村 博敏 坂井 千秋
出版者
Japanese Society of Radiological Technology
雑誌
日本放射線技術學會雜誌 (ISSN:03694305)
巻号頁・発行日
vol.69, no.11, pp.1232-1240, 2013-11-20
参考文献数
15
被引用文献数
1

<i>Background</i>: In coil embolization of neurovascular aneurysms, we have noted that few wide-necked unruptured aneurysms are successfully embolized. This prompted us to search for useful factors to assist the choice of methods of coil embolization. <i>Method</i>: We first measured aneurysm size and volume using auto measurement (NVvol) and VER (NVver). Second, we calculated the volume (NVapp) and VER (NVapp) using approximation expressions. Third, we measured the end-on view neck angle using a 3 dimensional digital subtraction angiography (3D-DSA) image. <i>Results</i>: NVvol and NVapp were correlated (<i>y</i>=0.87<i>x</i>). NVvol VER and NVapp VER approached 24% in 41 clinical cases. The dome/neck ratio averaged 1.15. Length of neck and the end-on view neck angle were significantly different between the stent-assisted group and the balloon-assisted group. NVvol and NVapp showed a good correlation with basic examination results in 41 clinical cases. <i>Conclusion</i>: The end-on view neck angle is significantly different. This boundary neck angle was 100° for the two groups. The end on-view neck angle is thus a useful factor for deciding medical treatment strategy.
著者
山口 功 石田 智一 木戸屋 栄次 東村 享治 鈴木 正行
出版者
公益社団法人日本放射線技術学会
雑誌
日本放射線技術學會雜誌 (ISSN:03694305)
巻号頁・発行日
vol.61, no.2, pp.260-267, 2005-02-20
被引用文献数
7

A strict determination of scan timing is needed for dynamic multi-phase scanning and 3D-CT angiography (3D-CTA) by multi-detector row CT (MDCT). In the present study, contrast media arrival time (T_<AR>) was measured in the abdominal aorta at the bifurcation of the celiac artery for confirmation of circulatory differences in patients. In addition, we analyzed the process of formation of the time-density curve (TDC) and examined factors that affect the time to peak aortic enhancement (T_<PA>). Mean T_<AR> was 15.57±3.75 s. TDCs were plotted for each duration of injection. The rising portions of TDCs were superimposed on one another. TDCs with longer injection durations were piled up upon one another. Rise angle was approximately constant in response to each flow rate. Rise time (T_R) showed a good correlation with injection duration (T_<ID>). T_R was 1.01T_<ID> (R^2=0.994) in the phantom study and 0.94T_<ID>-0.60 (R^2=0.988) in the clinical study. In conclusion, for the selection of optimal scan timing it is useful to determine T_R at a given point and to determine the time from T_<AR>.
著者
稲本 一夫
出版者
公益社団法人日本放射線技術学会
雑誌
日本放射線技術學會雜誌 (ISSN:03694305)
巻号頁・発行日
vol.51, no.9, pp.1275-1280, 1995-09-01
被引用文献数
1
著者
小倉 敏裕
出版者
公益社団法人日本放射線技術学会
雑誌
日本放射線技術學會雜誌 (ISSN:03694305)
巻号頁・発行日
vol.49, no.12, pp.2052-2057, 1993-12-01
被引用文献数
4

1.解像特性は, 同一インチモードにおいてもアイリス径とピクセル値がそれぞれ大きくなると低下することがわかった.このことは, I.I.への入射線量の増減により解像特性が変化することを意味する.aアイリス径を一定に保ち, 入射線量を増すとピクセル値が上昇し解像特性が低下する.bピクセル値を一定に保つためにアイリス径を広くし, 入射線量を減ずると解像特性が低下する.すなわち, 高い解像特性の画像を得るためには, アイリス径を絞り, 低いピクセル値となるような線量で撮影する.逆にあまり高い解像特性を必要としない場合, アイリス径を広くすることによって被曝低減が可能である.2.低線量撮影により, ルーチンに小焦点(0.2mm)撮影が可能である.このため, 小焦点拡大撮影の技法が応用でき, S/Fに匹敵する解像特性の有する画像が得られる.3.ノイズに関して, 線量の低減によって量子モトルが増加し, ディジタルWSは上昇した.そして, 同時に低コントラスト被写体検出能の低下も顕著であった.また, ノイズ特性は, 解像特性と密接な関係があるため, アイリス径や, ピクセル値によっても異なる.このように, I.I./TV-DRの場合, 入射線量と解像特性とノイズ特性の間には, 複雑な関係があり, これらの特性を熟知したうえで撮影目的にあったDR装置のパラメータの設定, 線量, 撮影方法を決定する必要がある.