著者
大江 光雄 小倉 一郎 鈴木 亘
出版者
公益社団法人日本放射線技術学会
雑誌
日本放射線技術學會雜誌 (ISSN:03694305)
巻号頁・発行日
vol.46, no.8, 1990-08-01

センターライン法のアルゴリズムを改良して良好な結果を得た。また正常例の解析結果を蓄積した。本開発に協力いただいた国立循環器病センター放射線技師の大西先生に感謝致します。
著者
宮下 五郎 鈴木 利久
出版者
公益社団法人日本放射線技術学会
雑誌
日本放射線技術學會雜誌 (ISSN:03694305)
巻号頁・発行日
vol.15, no.2, pp.158-162, 1959-12-10

In fluoroscopy, the best proportion among kVp, mA and FHD is essential for the most effective method of raising the hit rate of fluoroscopy and decreasing useless surface dose. The most important pre-condition is to keep the brightness of the fluorescent screen uniform. Under the absolution value of brightness, 0.05 cp/m^2 for objects, i.e. legs 8 cm thick, the change of X-ray energy corresponding to that of the thickness of the object at the same brightness, was drawn throgh the development factor and this relation was shown in a chart in order to investigate the theoretical grounds of the relation among kVp. mA and FHD. These experimental results were applied to clinical examinations and good results were obtained and reported here.
著者
青山 裕
出版者
公益社団法人日本放射線技術学会
雑誌
日本放射線技術學會雜誌 (ISSN:03694305)
巻号頁・発行日
vol.60, no.10, pp.1369-1373, 2004-10-20
被引用文献数
1

医療の倫理は,クライアントに責任を負う医師の視点から主に研究され,個別の問題をいかにすべきかを多様な立場から論じ,あるいは判例が検討されている.もちろん,倫理問題には明確な答えが存在するのではなく,各個人により判断,見解は相違する.クライアントの生死に身近でかかわることの少ない診療放射線技師にとって医療倫理を論じることには,違和感があるかもしれない.最良の画像を提供する医療行為の実施以前に,クライアントは被写体であり,繊細な感情を持った「ひと」である.一方,医療被曝については,技師の裁量に倫理は欠かせない.また,職域の問題もあり,臨床現場では他医療従事者との関係も含め,疑問,葛藤を感じることが多々生じる.クライアント中心の医療に医療技術者としていかに参加するか,技師にとっての倫理を考え,意識するということはどういうことか,医療倫理の四原則にアドボカシーを考慮しつつ考察する.
著者
花井 耕造 井原 文子 勝田 昭一 村松 禎久 村上 勉 井原 完有 藤田 智之 川合 英夫 田仲 隆 森山 紀之
出版者
公益社団法人日本放射線技術学会
雑誌
日本放射線技術學會雜誌 (ISSN:03694305)
巻号頁・発行日
vol.50, no.12, pp.1950-1959, 1994-12-01
被引用文献数
10

本研究ではAxial像を中心に, ヘリカルCTにおける再構成間隔と腫瘤性陰影の描出能の関係をコントラスト分解能の違いから述べた.ヘリカルCTでは, 検査目的に応じて最適な再構成間隔を定めることで, 体軸方向に対する情報量をいかに効率良く, かつ最大限に得るかが重要なスキャン条件の選択となる.今後, 3次元画像表示への対応も含めて最適再構成間隔の設定基準を定めて行きたい.
著者
川下 郁生 石田 隆行 桂川 茂彦 有村 秀孝 土井 邦雄
出版者
公益社団法人日本放射線技術学会
雑誌
日本放射線技術學會雜誌 (ISSN:03694305)
巻号頁・発行日
vol.56, no.3, pp.443-448, 2000-03-20
被引用文献数
1

Computer-aided diagnosis(CAD)system has been developing in the field of medical imaging. As CAD becomes more common in diagnostic radiology, it is expected that diagnostic performance will be improved. In actual use, however, the results of CAD might be affected by the quality of images, which are obtained under different exposure conditions and / or with differing devices. In this study, we investigated the effect of varied image quality on the results of texture analysis, a method developed by Katsuragawa, et al. and used in CAD for the detection of interstitial lung desease. To provide samples of varying image quality, we obtained images using various exposure doses and scatterer thicknesses. It was found that texture analysis was affected by differences in scatterer thickness.
著者
長岡 宏明 永峰 正幸 嶽間澤 博 松田 稔 鈴木 義久
出版者
公益社団法人日本放射線技術学会
雑誌
日本放射線技術學會雜誌 (ISSN:03694305)
巻号頁・発行日
vol.50, no.8, 1994-08-01

センサー自体に厚みがあるため、被写体に密着しての撮像が不可能となった。検知感度については光センサータイプが優れ、空気圧センサータイプは特に感度が鈍かった。しかし、感度が良すぎても、髪の毛や衣服などで検知する等、取扱上で不便な点もあった。外周センサータイプでは危険なほど圧迫してもセンサーが感知しないこともあった。
著者
畑川 政勝 井上 誠 庄垣 雅史 岸本 健治 吉田 梨影
出版者
公益社団法人日本放射線技術学会
雑誌
日本放射線技術學會雜誌 (ISSN:03694305)
巻号頁・発行日
vol.48, no.11, pp.1932-1938, 1992-11-01
被引用文献数
13

The modulation transfer function (MTF) has been used for evaluation of radiographic image quality. However, in digital radiographic system such as a computed radiography (CR), the MTF can not be used in the same way of an analog system for evaluation because digital system is not shift-invaliant system. Then, we suggest the "MTF_<final>" which includes geometric unsharpness, detector unsharpness, unsharpness of the sampling aperture and unsharpness of the display (Laser-printer). It is an analog component in the digital system and in agreement with the definition of the MTF. Furthermore, an overall aliasing has to be used with MTF_<final> for evaluating the digital system because it is one of the important factors of the digital system. The MTF_<final> and the overall aliasing can be obtained from the overall MTFs of the center alignment and the shifted alignment.