著者
辻 敏和 永田 健一郎 川尻 雄大 山田 孝明 入佐 俊弘 村上 裕子 金谷 朗子 江頭 伸昭 増田 智先
出版者
公益社団法人 日本薬学会
雑誌
YAKUGAKU ZASSHI (ISSN:00316903)
巻号頁・発行日
vol.136, no.11, pp.1573-1584, 2016 (Released:2016-11-01)
参考文献数
20
被引用文献数
2

There are many reports regarding various medical institutions' attempts at the prevention of dispensing errors. However, the relationship between occurrence timing of dispensing errors and subsequent danger to patients has not been studied under the situation according to the classification of drugs by efficacy. Therefore, we analyzed the relationship between position and time regarding the occurrence of dispensing errors. Furthermore, we investigated the relationship between occurrence timing of them and danger to patients. In this study, dispensing errors and incidents in three categories (drug name errors, drug strength errors, drug count errors) were classified into two groups in terms of its drug efficacy (efficacy similarity (−) group, efficacy similarity (+) group), into three classes in terms of the occurrence timing of dispensing errors (initial phase errors, middle phase errors, final phase errors). Then, the rates of damage shifting from “dispensing errors” to “damage to patients” were compared as an index of danger between two groups and among three classes. Consequently, the rate of damage in “efficacy similarity (−) group” was significantly higher than that in “efficacy similarity (+) group”. Furthermore, the rate of damage is the highest in “initial phase errors”, the lowest in “final phase errors” among three classes. From the results of this study, it became clear that the earlier the timing of dispensing errors occurs, the more severe the damage to patients becomes.
著者
増田 智先 山本 由貴
出版者
日本DDS学会
雑誌
Drug Delivery System (ISSN:09135006)
巻号頁・発行日
vol.33, no.5, pp.397-405, 2018-11-25 (Released:2019-02-25)
参考文献数
24
被引用文献数
1

メサラジン(別名:メサラミン、5-アミノサリチル酸、5-ASA)は、潰瘍性大腸炎とクローン病からなる炎症性腸疾患の第1選択薬として使用される。5-ASAの有効性は、炎症部位への薬物送達の程度によって決定されるが、それは製剤により異なる。近年、特に潰瘍性大腸炎に対する治療薬としてdrug delivery system(DDS)技術を駆使した5-ASA製剤が次々と開発されており、治療効果向上に貢献している。そこで本稿では、それぞれの5-ASA製剤の薬物動態学的特徴に着目し、製剤の有する特徴と臨床的有用性について紹介する。
著者
佐野 梓 末次 王卓 秦 晃二郎 柊迫 美咲 片山 美幸 田中 瑠美 田島 壮一郎 グリム 理恵子 辻 敏和 渡邊 裕之 金谷 朗子 増田 智先
出版者
一般社団法人日本医療薬学会
雑誌
医療薬学 (ISSN:1346342X)
巻号頁・発行日
vol.44, no.5, pp.229-235, 2018-05-10 (Released:2019-05-10)
参考文献数
16
被引用文献数
4

We have disclosed 14 standardized laboratory data on out-of-hospital prescriptions since June 2015. In this study, we analyzed questions on out-of-hospital prescriptions related to laboratory data over 2 years. There were 229 prescription questions related to laboratory data (3.4% of the total prescription questions), and 79.5% of these were related to renal function. Among renal function-associated laboratory data, serum creatinine was used in most cases. The rate of prescription change after prescription questions was 66.5% for laboratory data associated with renal function, which was significantly higher (P < 0.001) than the 25.5% for other types of data. Furthermore, the clear description of dose reduction requirements on a package insert was confirmed to be one of the common factors for renal excretory drugs. Therefore, it is important to provide renal function laboratory data to facilitate the appropriate adjustment of out-of-hospital prescription doses. In addition, to enable appropriate dose adjustments using laboratory data, the description on the drug package insert should make it easy for pharmacists who are auditing prescriptions to make appropriate judgments.
著者
乾 賢一 矢野 育子 増田 智先
出版者
京都大学
雑誌
萌芽研究
巻号頁・発行日
2006

研究代表者等はこれまでに、生体肝移植患者において、シクロスポリンやタクロリムスの標的分子であるカルシニューリンの酵素活性が、これら薬物の免疫抑制効果の指標となり得ることを明らかにしてきた。本研究では、臨床応用可能な迅速かつ高感度な新規カルシニューリン活性測定法の開発を目指して、ELISA法を用いた測定系について検討した。現在までに、カルシニューリンの特異的基質であるリン酸化RIIペプチドに対する抗リン酸化ペプチド抗体の作成に成功し、さらに抗体の特異性が確認された。続いて、抗リン酸化RIIペプチド抗体をプレートに固相化し、FLAG付リン酸化RIIペプチドを標準物質として、サンドイッチELISA測定系を確立した。FLAG付リン酸化RIIペプチドの定量性は、0.125-4ng/mLの範囲であった。本法は、カルシニューリンによるリン酸化RIIペプチドの脱リン酸化反応(ステップ1)と、FLAG付リン酸化RIIペプチドによる反応終了液中に含まれるリン酸化RIIペプチドの定量(ステップ2)を行うことを特徴とし、反応前後のリン酸化RIIペプチドの物質収支からカルシニューリンの脱リン酸化活性が算出できる。本年度は、リン酸化RIIペプチド定量のための条件検討を実施した。まず、ステップ1の停止液のステップ2に対する影響を調べた結果、常用の5%トリクロロ酢酸/0.lMリン酸二水素カリウム溶液を用いた場合、FLAG付リン酸化RIIペプチド(4ng/mL)の検出が不可能であった。そこで次に、5mM EGTA(カルシニューリンの阻害剤)をステップ1の停止液として用いた場合、ステップ2には影響せず、FLAG付リン酸化RIIペプチドの検出が可能であることが示された。今後、開発したnon-RI ELISA測定系の臨床応用に向けて、カルシニューリン活性測定の最適化及び全自動化を目指す予定である。