著者
長谷川 兼一 鍵 直樹 坂口 淳 篠原 直秀 白石 靖幸 三田村 輝章
出版者
日本建築学会
雑誌
日本建築学会環境系論文集 (ISSN:13480685)
巻号頁・発行日
vol.86, no.780, pp.197-204, 2021 (Released:2021-02-28)
参考文献数
21
被引用文献数
2

A recent meta-analysis of dampness in homes has shown that dampness and mold in indoor environments are factors in approximately 30-50% of all respiratory and asthma-related health ailments. Although the specific indoor dampness factors related to such issues have yet to be fully explored, there are clear and urgent needs for improved architectural techniques and optimized occupant behavior patterns that can prevent or eliminate excessive dampness inside buildings. Furthermore, if the underlying structures linking dampness to adverse health effects could be more closely estimated through epidemiological surveys, prevention methodologies for serious problems related to indoor dampness might be discovered. With these points in mind, we previously proposed a home dampness estimation method based on occupants’ self-reported answers to questions regarding indoor dampness during winter. This resulted in an indoor dampness index covering a range from 0 to 24 that classifies houses into four ranks, with those in Rank 4 presenting the most serious dampness-related problems. To clarify the relationship between home dampness levels and indoor environmental quality, another questionnaire survey was conducted and several physical environmental items such as indoor temperature, humidity, and microbial flora from floor dust were measured in 119 detached East Japan houses during the winter season. Herein, we describe the surveyed results and the distribution of the dampness index. The questionnaire also included child health-related symptoms that show onsets within 3 months, and the prevalence of each symptom is presented in relation to each dampness index rank. The characteristics of indoor temperature and humidity resulting from home dampness levels were also clarified by comparing the dampness index and measured results of these physical items. Analyzing the survey results, we found that the prevalence of nasal- and eye-related symptoms increased approximately in tandem with the dampness index ranking. In particular, more than 50% of the children residing in Rank 4 homes reported nasal problems, and there was a high prevalence of throat and skin symptoms in Rank 3 homes. However, despite these values, there are still no clear links between the dampness index and the reported health-related symptoms. Next, the statistical values of temperature, relative humidity, and the humidity ratio during evening time in living rooms and bedrooms were analyzed for each dampness index rank. To test the significance of these associations, Kruskal-Wallis testing was performed to determine whether the samples in each dampness index rank originate from the same distribution. Moreover, the significant differences among each rank’s samples were tested in multiple comparisons. As for temperature results, no significant association was found among the dampness index ranks. This presumes that living room temperatures are affected by heating behaviors at the time of occupancy. On the other hand, both the relative humidity level and the humidity ratio were found to be strongly associated with the dampness index rankings; with higher humidity levels in the living room and bedroom presaging higher dampness index ranks. In addition, the relative humidity and humidity ratios in Rank 2, 3, and 4 living rooms were significantly higher in comparison with Rank 1 living rooms, while the median relative humidity values in Rank 4 living rooms and bedrooms were around 50% and 70%, respectively. Significantly, the humidity ratios in Rank 4 homes were found to be the highest among the surveyed houses and it was expected that these houses had severe environmental problems related to indoor dampness.
著者
林 基哉 小林 健一 金 勲 開原 典子 柳 宇 鍵 直樹 東 賢一 長谷川 兼一 中野 淳太 李 時桓
出版者
公益社団法人 空気調和・衛生工学会
雑誌
空気調和・衛生工学会大会 学術講演論文集 令和元年度大会(札幌)学術講演論文集 第7巻 空気質 編 (ISSN:18803806)
巻号頁・発行日
pp.45-48, 2019 (Released:2020-10-31)

事務所の衛生環境の実態を把握するため特定建築物の行政報告例の分析、事務所の空気環境の調査を行う。本報告では空気環境不適率の上昇要因を明らかにするため、行政報告例不適率の実態を把握し、不適率上昇の要因に関する統計解析を行った。特定建築物数が増加する中、湿度、温度、二酸化炭素濃度の不適率が1999年以降上昇している。また、法定検査を利用した報告徴取が増加している。湿度、温度、CO2濃度の不適率上昇の要因として報告徴取数の増加が挙げられ、これらの不適率は、北の自治体ほど高い傾向がある。
著者
西村 直也 柳 宇 鍵 直樹 池田 耕一 吉野 博 斉藤 秀樹 斉藤 敬子 鎌倉 良太 小畑 美知夫
出版者
公益社団法人 空気調和・衛生工学会
雑誌
空気調和・衛生工学会 論文集 (ISSN:0385275X)
巻号頁・発行日
vol.36, no.175, pp.1-8, 2011-10-05 (Released:2017-09-05)
参考文献数
10
被引用文献数
2

本研究は医療施設における室内空気環境の維持管理のあり方について検討することを目的とする。第1報では調査の詳細および冬期、夏期における計18件の病院の外来待合室、事務室および病室に対する建築物衛生法の測定方法に準じた空気質の実測調査結果を示した。また第2報では浮遊微生物濃度の実態を明らかにした。第1、2報では建築物衛生法の環境基準値およびHEAS指針値を超過する室が多く見られ、適切に運用するためには、空気環境について定期的に監視することが有効であるという見解が得られた。本報では、温熱環境、空気質について連続測定や定量分析を行うことによって、より詳細に実態の解析を行った。その結果、室によっては温熱環境の日中変動が大きいこと、室内の浮遊粉じん濃度が外気の濃度に大きく影響を受けていること、VOC類の濃度は概ね低く抑えられているものの、DEGEEやカンファーなどが特徴的に検出されることなどを確認した。
著者
柳 宇 鍵 直樹 池田 耕一
出版者
日本建築学会
雑誌
日本建築学会環境系論文集 (ISSN:13480685)
巻号頁・発行日
vol.75, no.654, pp.721-726, 2010-08-30 (Released:2010-10-08)
参考文献数
14

The “Law for Maintenance of Sanitary Environment in Buildings (established in 1970)” was revised in 2002. According to the revision, individual air-conditioning system was set as the object of the law. However, since it was the outside for the way until now, the actual status of the microbial contamination in an individual air-conditioning system is not known well. In this study, an office building with an individual air-conditioning system, in which occupants' complain on mould smell, was select to the measurement object. As a result of performing the detailed survey and questionnaire on microbial contamination, it became clear that the "mould smelly" was caused by the fungi in a humidifier.
著者
安藤 真太朗 白石 靖幸 長谷川 兼一 坂口 淳 三田村 輝章 鍵 直樹 篠原 直秀
出版者
公益社団法人 空気調和・衛生工学会
雑誌
空気調和・衛生工学会大会 学術講演論文集
巻号頁・発行日
vol.2016, pp.213-216, 2016

<p>本研究では、結露とカビ発生に関する各指標がアレルギー性疾患に及ぼす影響を明らかにすること及び、自宅の周辺環境による影響を考慮するために、マルチレベル分析等の多変量解析を実施した。結果として、カビが複数箇所で発生している住居に住む児童ほどアレルギー性疾患を有する可能性が高く、また、地域性を考慮しても個人レベルでは「カビの発生」が、都道府県レベルでは「交通量」や「工場」等の周辺環境がアレルギー疾患に影響を与えていることが示された。</p>
著者
鍵 直樹
出版者
国立保健医療科学院
雑誌
若手研究(B)
巻号頁・発行日
2009

フタル酸ジエチルヘキシルのような準揮発性有機化合物(SVOC)は,喘息だけでなく化学物質過敏症の原因になっている。室内空気中のSVOCは,蒸気圧が低いために単体の分子(ガス相)あるいは,浮遊粉じん上(粒子相)の双方に存在する。しかし,これらの分配係数の測定法が必ずしも確立されているとは言い難い。そこで本研究では,超音波アトマイザで関東ロームの試験浮遊粉じんを発生させて,拡散チューブを用いてガス相および粒子相のDEHPの分離測定を行うことを試みた。その結果の1つとして,特定の条件下においてガス状DEHPの試験浮遊粉じんへの吸着特性はラングミユア型を示すことが示唆された。