著者
中平 敦 武田 真一 塩見 治久 大西 宏司
出版者
The Ceramic Society of Japan
雑誌
Journal of the Ceramic Society of Japan (日本セラミックス協会学術論文誌) (ISSN:09145400)
巻号頁・発行日
vol.107, no.1247, pp.662-667, 1999-07-01 (Released:2010-08-06)
参考文献数
29

Effect of alcohol solvent in mixing process on the microstructure and sintering behavior of ceramic-based composites was investigated in detail. The mixture of fine ceramic powders was prepared through the conventional ball-milling method with various alcohol media. The particle distributions of fine ceramic powders were strongly dependent on the kind of alcohol employed during ball-milling. Ceramic-based composites were fabricated by hot-pressing the mixture of fine ceramic powders. Their microstructures and some mechanical properties of the ceramic-based composites were evaluated. It was found that the viscosity of alcohol, surface tension and contact angle greatly affect the sinterability and some of the mechanical properties of ceramic-based composites.
著者
武田 真一 中田 慎二 田里 伊佐雄
出版者
The Ceramic Society of Japan
雑誌
Journal of the Ceramic Society of Japan (日本セラミックス協会学術論文誌) (ISSN:09145400)
巻号頁・発行日
vol.99, no.1146, pp.141-145, 1991-02-01 (Released:2010-08-06)
参考文献数
31
被引用文献数
1 1

Post-indentation slow crack growth in soda-lime-silica glass in various aqueous RNO3 (R+; Li+, Na+, K+, Rb+) solutions was investigated in order to understand the mechanism of stress corrosion of glass. The crack growth was found to depend on both the concentration and the nature of the supporting electrolytes. The crack growth was enhanced by the change in the concentration of alkali metal ions from 10-4-1M, and also by the nature of alkali metal ions in the order of Hofmeister series Li+<Na+<K+<Rb+ at the ion concentration of 10-2M. These behaviors showed that the results obtained can be interpreted in terms of the molecular structure of the glass/electrolyte interface based on the charged states.
著者
城 潤一郎 三島 史人 武田 真一 山本 雅哉 村垣 善浩 伊関 洋 佐保 典英 窪田 純 佐々木 明 西嶋 茂宏 田畑 泰彦
出版者
日本DDS学会
雑誌
Drug Delivery System (ISSN:09135006)
巻号頁・発行日
vol.22, no.5, pp.558-568, 2007 (Released:2007-12-13)
参考文献数
5
被引用文献数
7 6

次世代DDS型治療システムとは,従来のDDS治療効果をさらに向上させるために,外部エネルギーをDDS技術と融合させる新しい技術・方法論である.この新治療システムによって,体内の深部にある病気を治療できるであろう.本稿では,磁場とDDSとを組み合わせた,磁気誘導DDSによる次世代治療システムを実現させるために必要となる技術要素を概説するとともに,その治療ポテンシャルについて述べる.
著者
武田 真一郎
出版者
水資源・環境学会
雑誌
水資源・環境研究 (ISSN:09138277)
巻号頁・発行日
vol.1998, no.11, pp.21-30, 1998-12-25 (Released:2009-04-22)

吉野川第十堰建設事業とは、江戸時代に築かれた現在の第十堰を撤去し、長良川と同様の可動堰を建設するというものである。堰の大きさは長良川河口堰を上回り、徳島県民一人あたり12万円を要する巨大な公共事業である。事業が必要とされる根拠は、せき上げ、老朽化、深掘れという治水上の理由である。しかし、市民団体からは、建設省のせき上げ水位計算は過大であり、実際には水害の危険はないことが指摘されるなど、事業の必要性には疑問が示されている。また、長良川河口堰のように環境や財政に大きな負担をかけることも懸念されている。世論調査の結果では反対意見が53.7%に達しているが、地元の議会は次々と推進決議を行い、建設省の審議委員会も計画を妥当とする意見をまとめた。そこで、徳島市では住民投票によって民意を明らかにするために、住民投票条例の制定を求める直接請求が行われている。
著者
尾崎 剛 寺田 隆哉 武田 真一 泉 佳伸 西嶋 茂宏
出版者
The Society of Life Support Engineering
雑誌
ライフサポート (ISSN:13419455)
巻号頁・発行日
vol.19, no.1, pp.3-8, 2007-03-30 (Released:2010-07-21)
参考文献数
8

The stress induced during visual display terminals tasks in various environments was researched. One subject was made to do visual display terminals. The stress induced during visual display terminals tasks was evaluated using concentration of cortisol in saliva, sensory value, and work efficiency. In addition, the correlation between them was studied. New indices concerning stress and work efficiency were derived by means of the multivariate analysis. It was found that two new indices were enable to design a comfortable working environment.
著者
佐々木 信博 上野 幸司 白石 武 吉村 章 久野 宗寛 武田 真一 斎藤 孝子 安藤 康宏 草野 英二
出版者
The Japanese Society for Dialysis Therapy
雑誌
日本透析医学会雑誌 = Journal of Japanese Society for Dialysis Therapy (ISSN:13403451)
巻号頁・発行日
vol.41, no.10, pp.723-730, 2008-10-28
被引用文献数
2 5

近年われわれは,高精度体成分分析装置(InBody S20)を用いた生体電気インピーダンス(BIA法)が血液透析患者の体液量評価に有用であることを報告し,特に浮腫値(細胞外水分量(ECW)/体水分量(TBW))やInBody S20でのDW(BIA-DW)が,臨床的DW(Cl-DW)の一つの指標となることを報告した.今回われわれは,糖尿病,心不全,低アルブミン血症,透析低血圧例,肥満患者,透析期間,尿量維持患者などの各種疾患や病態別に透析後の浮腫値を中心に具体的なDW設定基準について検討を行った.対象は当院で維持透析を施行している57名で,透析前後でInBody S20による各種体液量と血液一般検査,透析後にhANP,BNP,胸部X線による心胸郭比(CTR),心臓超音波検査による下大静脈(IVC)径,左室駆出率(EF)などを測定した.全ての病態で浮腫値は透析後に有意に低下した(p<0.0001).透析後浮腫値は,血清Alb値と負の相関を示し(r=-0.720,p<0.0001),糖尿病群では非糖尿病群にくらべ有意に高値を示した(p<0.0001).そこで,糖尿病と低Alb血症の有無による4群での検討を行った.透析後浮腫値は,I群(DM(-),低Alb(-)):0.384±0.005にくらべ,II群(DM(-),低Alb(+)):0.397±0.013,III群(DM(+),低Alb(-)):0.398±0.011で有意に高値を示し(p<0.001),IV群(DM(+),低Alb(+)):0.404±0.012で最も高値を示した(p<0.0001).InBody S20で求められる理想的なDW(BIA-DW;浮腫値0.380のBW)と実際の臨床的DW(Cl-DW)は,強い正相関(r=0.996,p<0.0001)を示し,I群においてはその値はほぼ一致し,II群,III群においてはBIA-DWよりも0.5~0.8kg程度上乗せした体重が,IV群では1kg程度上乗せした体重がCl-DWとなることが示された.一方,浮腫値は,血圧,心機能,透析期間,尿量とは相関を認めなかった.InBody S20で求められる透析後浮腫値は,原疾患の有無にかかわらず,透析患者のDWの一指標となりうると考えられた.
著者
荒尾 与史彦 小柳 潤 武田 真一 宇都宮 真 川田 宏之
出版者
一般社団法人 日本機械学会
雑誌
日本機械学会論文集A編 (ISSN:18848338)
巻号頁・発行日
vol.77, no.776, pp.619-628, 2011 (Released:2011-04-25)
参考文献数
17
被引用文献数
7 8

Strict geometrical stability is required for the precise structures like telescopes. Unpredictable out-of-plane deformation is a serious problem when we use CFRP (Carbon Fiber Reinforced Plastic) laminate to the precise structure. This out-of plane deformation of symmetrical CFRP laminate mainly arise from combination effects of ply angle misalignment and temperature change. We discussed here is effective stacking sequence of CFRP laminate that mitigate the deformation caused by the ply angle misalignment. The analysis based on laminate theory was performed to calculate the thermal deformation. In this analysis, the random numbers were added to each layers as ply angle misalignments. The analytical results were obtained statistically by Monte Carlo method. Mohr's curvature circle was also incorporated to evaluate the deformation as P-V (peak to Valley) values. We performed the analysis with various stacking sequence. It was calculated that the symmetric cross-ply laminates deformed 10 times larger than the other quasi-symmetric laminates. In the case of the total ply number is less than 12, the stacking sequence in the laminate has a significant effects on the thermal deformation. However, if the total number ply number is more than 24, effect of stacking sequence on the thermal deformation becomes negligible. We also discussed the geometrical stability of CFRP mirror by considering unavoidable ply angle misalignment. It was presumed that the CFRP mirror can be used for wide range of wave length when the back structure was attached to CFRP laminates.