著者
池内 隆夫
出版者
泌尿器科紀要刊行会
雑誌
泌尿器科紀要 (ISSN:00181994)
巻号頁・発行日
vol.36, no.7, pp.801-806, 1990-07

西洋医学治療の結果,難治・再発した慢性非細菌性前立腺炎と前立腺炎様症候群の症例に対し漢方療法を試みた.1)漢方療法の臨床効果は,慢性非細菌性前立腺炎61例では著効率21.3%,臨床的有効率67.2%であり,前立腺炎様症候群82例では著効率19.5%,臨床的有効率52.4%であった.2)漢方単独療法と西洋薬併用治療群の効果を比較すると,前立腺炎様症候群では両群間に差はないが,慢性非細菌性前立腺炎では漢方単独群より抗菌剤併用群の方が効果が優れていた(p<0.1).3)慢性非細菌性前立腺炎での併用抗菌剤の効果では,new-quinolon系薬剤がST合剤やtetracycline系薬剤より良好であった.4)使用漢方薬の臨床効果を検討し,両病型ともに桂枝茯苓丸と四物湯の効果が良好であった.5)漢方療法での副作用発現率は9例6.3%であり,桂枝茯苓丸の投与例に多かった
出版者
筑波大学心理学系
雑誌
筑波大学心理学研究 (ISSN:09158952)
巻号頁・発行日
no.44, pp.131, 2012-08-10
著者
清水 政行
出版者
[出版者不明]
巻号頁・発行日
2010-07

制度:新 ; 報告番号:甲3147号 ; 学位の種類:博士(学術) ; 授与年月日:2010/7/15 ; 早大学位記番号:新5428
著者
Min Eun Jung Shin Jun Geun Lee Jae Hwi Yasuno Yoshiaki Lee Byeong Ha
出版者
Optical Society of America
雑誌
Optics letters (ISSN:01469592)
巻号頁・発行日
vol.37, no.15, pp.3105-3107, 2012-08
被引用文献数
7

We present a full range handheld probe type spectral domain optical coherence tomography (SD-OCT) method. Here, the sample arm is composed of a tilted fiber-optic cantilever scanner; thus, the phase shift concurrently occurs while sample scanning. With the phase shift, we could achieve a full range complex-conjugate-free OCT image with no additional phase shifters in the reference arm. To realize this technique, a magnetically actuated probe was adopted. Full range SD-OCT images of a pearl, human fingernail, and human tooth were subsequently obtained using this suggested probe. The scanning range and acquisition speed were 3 mm and 20  frames/s, respectively.
著者
Yamanari Masahiro Ishii Kotaro Fukuda Shinichi Lim Yiheng Duan Lian Makita Shuichi Miura Masahiro Oshika Tetsuro Yasuno Yoshiaki
出版者
Public Library of Science
雑誌
PLoS ONE (ISSN:19326203)
巻号頁・発行日
vol.7, no.9, pp.e44026, 2012-09
被引用文献数
26 5

PurposeTo investigate a relationship between birefringence and elasticity of porcine sclera ex vivo using polarization-sensitive optical coherence tomography (PS-OCT).MethodsElastic parameters and birefringence of 19 porcine eyes were measured. Four pieces of scleral strips which were parallel to the limbus, with a width of 4 mm, were dissected from the optic nerve head to the temporal side of each porcine eye. Birefringence of the sclera was measured with a prototype PS-OCT. The strain and force were measured with a uniaxial material tester as the sample was stretched with a speed of 1.8 mm/min after preconditioning. A derivative of the exponentially-fitted stress-strain curve at 0% strain was extracted as the tangent modulus. Power of exponential stress-strain function was also extracted from the fitting. To consider a net stiffness of sclera, structural stiffness was calculated as a product of tangent modulus and thickness. Correlations between birefringence and these elastic parameters were examined.ResultsStatistically significant correlations between birefringence and all of the elastic parameters were found at 2 central positions. Structural stiffness and power of exponential stress-strain function were correlated with birefringence at the position near the optic nerve head. No correlation was found at the position near the equator.ConclusionsThe evidence of correlations between birefringence and elasticity of sclera tested uniaxially was shown for the first time. This work may become a basis for in vivo measurement of scleral biomechanics using PS-OCT.