This paper reports the results of a field survey on the indoor thermal environment in two terraced houses in Johor Bahru city, Malaysia. The survey was carried out in a single-story house and a two-story house. The results show that opening windows not only affects ventilation but also controls the influence of the outside thermal environment. Moreover, on the double-story house, the upper floor has the function of thermal insulation for the ground floor.
著者
鏡味 洋史
出版者
一般社団法人日本建築学会
雑誌
日本建築学会技術報告集 (ISSN:13419463)
巻号頁・発行日
no.15, pp.363-366, 2002-06-20
被引用文献数
8

Off Miyagi-ken Earthquakes have been occurred repeatedly with an interval of around 40 years. Twenty-three years have been passed since the occurrence of the 1978 earthquake and the next one is expected in near future. As the previous earthquakes before 1978 event, 1936 and 1897 earthquakes can be cited. In this paper, literature survey with newspaper articles for 1897 event was carried out.
著者
片山 忠久 石井 昭夫 西田 勝 堤 純一郎 森川 明夫 橋田 光明
出版者
一般社団法人日本建築学会
雑誌
日本建築学会計画系論文報告集 (ISSN:09108017)
巻号頁・発行日
no.372, pp.p21-29, 1987-02
被引用文献数
7

Simultaneous observations of the profiles of wind velocity and air temperature are conducted at three points in an urban area with a large pond by the kytoons. From the results of observations, convective heat flux from the ground surface to air is calculated by the traverse-method. Heat flux from the pond is negative, that is, cooling. The relation between convective heat transfer coefficient and wind velocity is obtained in extensive built-up areas. Thermal environment is observed, formed at the height of 1 meter from the ground surface in the built-up area and the large pond. New standard effective temperature of the ASHRAE, SET, is calculated as the over all thermal index at the both sites. The effects of a shade tree and wisteria trellis on thermal environment are discussed.