著者
山本 匡 岩崎 清隆 新井 淳 北原 茂実 梅津 光生
出版者
公益社団法人 日本生体医工学会
雑誌
生体医工学 (ISSN:1347443X)
巻号頁・発行日
vol.51, no.6, pp.350-356, 2013-12-10 (Released:2014-03-28)
参考文献数
11

Percutaneous coronary intervention (PCI) for ischemic heart disease became a common therapy. The improvement of treatment results was caused by invention of drug-eluting stent (DES) but its implantation procedure for pressure and inflation time has not been discussed. 3-time-balloon-inflation method is proved to be an effective method for inflation in in vitro experiments and it was practiced in the clinical field. The purpose of this study is to determine the effectiveness of the 3-time-balloon-inflation method and investigate the factors that cause suppression of stent expansion. From January 2011 to March 2012, PCI with drug-eluting stent (XIENCE V) were performed to 169 patients by a single-operator with 3-time-ballon-inflation method. Minimal lumen area (MLA), vessel cross-sectional area, and plaque cross-section in the MLA were measured by intravascular ultrasound (IVUS) before stent implantation. Minimum stent area (MSA) was measured after stent implantation. Stent expansion ratio (SER) was calculated from assumed area and MSA. Area acquisition ratio (AAR) was calculated from MSA and MLA. Subsequently, the ratio of calcification in the lesion was measured using the color mapping function mounted on the IVUS. The stent diameter used in this study was 2.89±0.35[mm] (mean±SD), stent length was 20.5±6.2[mm] (mean±SD), and the stent expansion pressure was 10.3±2.4[atm] (mean±SD). There was no difference in SER by stent size, target vessels, and MLA. Significant difference was seen in the calcification ratio between the group without pre-dilatation (n=27) and the group with pre-dilatation (n=142), but no difference in SER between the two groups. It was suggested that calcification ratio is one of the factors that causes the suppression of stent expansion because significance of calcification ratio came out in AAR.
著者
人見 真由 倉田 真宏 相田 伸二 下戸 学 趙 晃済 大鶴 繁
出版者
公益社団法人 日本生体医工学会
雑誌
生体医工学 (ISSN:1347443X)
巻号頁・発行日
vol.60, no.6, pp.139-148, 2022-12-10 (Released:2023-03-11)
参考文献数
38

This research examined the seismic behavior of medical equipment, which supports advanced hospital functions through shaking table testing and numerical analysis, and derived evaluation index for mitigating damage. The shaking table test observed the rocking and overturning of neonatal beds and a dialysis liquid feeding apparatus under sine waves and the building floor responses during earthquakes. The rocking and overturning damage occurred only when the casters of equipment were all locked, and the ratio between the equipment’s gravity center height (h) and leg width (b), b/h, is smaller than a certain threshold. The influence of equipment dimensions and weight on the seismic behavior was studied by parametric analysis using a distinct element method (DEM) model of equipment. The probability of damage decreased significantly when the ratio between the b/h becomes large. For the floor velocity response of 80cm/s, which is assumed for the approximate return period of 500 years and with the response amplification factor (the ground to floor response ratio) of 1.6, the probability of overturning became negligible when the b/h is 0.4 or larger. This paper also presents an analytical equation to calculate sufficient safety weights added to existing equipment for conforming to the above thresholds of b/h.
著者
赤澤 堅造 一ノ瀬 智子 前田 義信 奥野 竜平
出版者
公益社団法人 日本生体医工学会
雑誌
生体医工学 (ISSN:1347443X)
巻号頁・発行日
vol.Annual60, no.Proc, pp.275-277, 2022 (Released:2023-05-12)

筆者らは認知症に対する楽器演奏,音楽療法に関心があり,エビデンスに関して文献レビューを実施して,楽器演奏が健常者の認知症リスクを減少させる効果があることを報告した.当学会大会でも報告した(第1報(2018),第2報(2019)).筆者らは,演奏初心者でも本格的な演奏が楽しめるアクセシブルな電子楽器サイミスを開発しており,短期であるが,地域の健康な高齢者を対象としたサイミス応用の準備的な研究を実施した.ここで判明したことは,認知症予防のためのプロトコルを策定する必要があることである.最近,健常者,MCI者に対する音楽介入のランダム化比較試験の報告がいくつかあるので,プロトコル策定の手がかりをえるために,「認知機能」に焦点を当て文献レビューを実施した.本発表では,その文献レビュー結果を報告する.
著者
笠原 和美 DaSalla Charles 本田 学 花川 隆
出版者
公益社団法人 日本生体医工学会
雑誌
生体医工学 (ISSN:1347443X)
巻号頁・発行日
vol.Annual57, no.Abstract, pp.S279_1, 2019 (Released:2019-12-27)

ブレイン・マシン・インターフェイス(BMI)は、読み取った脳活動から機械を動かすことで、病気や怪我により失われた機能を代替する技術として注目されている。しかし、BMIの操作能力には個人差があり、上手く使いこなせないケースも多い。本研究は、運動想像に伴うμ波脱同期を用いた脳波BMIの操作能力を計測し、脳構造・機能との関係を明らかにした。健常者30名を対象とし、自身の手のタッピング動作を想像するように指示した。μ波脱同期の強度をオンラインで計算し、カーソルの制御信号として利用した。カーソルの操作能力を変数として、大脳皮質密度との相関を脳構造MRIにより調べた。さらに、脳機能MRIと脳波BMIの同時計測を用い、操作能力の差がある被験者間の脳機能連絡の違いを調べた。その結果、高い操作能力を有する被験者ほど運動想像に関係する補足運動野の皮質体積が大きく、運動野-基底核の運動ネットワークを利用していた。一方、操作能力の低い被験者は、背側前頭前野や前部帯状回など認知的なネットワークを利用していた。本研究で得られた知見を基に、高い操作性を有するBMIの開発が可能と考えられる。
著者
小幡 大輔 黒田 聡 菅原 俊継 早川 康之 清水 久恵 髙橋 昌宏
出版者
公益社団法人 日本生体医工学会
雑誌
生体医工学 (ISSN:1347443X)
巻号頁・発行日
vol.Annual60, no.Abstract, pp.82_2, 2022 (Released:2022-12-01)

[はじめに]これまで我々は、磁性粒子を利用して血液回路関連の異常対応訓練シミュレータについて、主に透析の条件で検討してきた。今後、アフェレシスやECMO等への仕様拡大を目指しているが、特にアフェレシスのように低流量であると、磁性粒子が沈降して血液回路内を循環できない可能性が考えられた。そこで本報告では、磁性粒子が血液回路内で循環可能な限界流量について検証した。[方法]血液回路(内径4mm、全長150cm)を水平に設置し、粒子径20µmの磁性粒子懸濁液を50mL/minから400mL/minの透析とアフェレシスを想定した流量で、ローラポンプにより循環させた。循環中に血液回路の流入口と流出口を撮影し、その際の流動状態と画像から推定された磁性粒子の量を比較した。[結果] 磁性粒子懸濁液は、100mL/minより流出口まで一様に堆積を伴う流れとなり、160mL/minより均質流であった。また、磁性粒子の量は、100mL/minまで流入口に対して流出口の方が少なかったが、120mL/minより同量となった。[まとめ]磁性粒子が血液回路内で循環可能な限界流量は120mL/minであることが示唆された。しかし、アフェレシスを想定すると50mL/minで循環させるため、粒子径を小さくする等の検討が必要である。また、臨床を想定すると血液回路の様々な設置の条件での検討が必要であると考えられた。
著者
河内山 隆紀
出版者
公益社団法人 日本生体医工学会
雑誌
生体医工学 (ISSN:1347443X)
巻号頁・発行日
vol.55Annual, no.4PM-Abstract, pp.357, 2017 (Released:2017-09-13)

過去20年にわたり、機能的磁気共鳴画像法(fMRI)は脳活動計測実験に広く利用されてきた。その主な原理であるblood oxygenation level dependent(BOLD)効果は、血液内の赤血球に含まれる色素である還元ヘモグロビンを内因性の造影剤として用いている。還元ヘモグロビンは常磁性体であり、その周辺に磁場の乱れを生み、局所的なMR信号強度の減少をまねく。つまりMRI画像で「見える」のである。一方、脳の神経活動の増加は、脳酸素代謝量の増加に比べて大きな脳血流量の増加を引き起こす。その結果、単位体積あたりの還元ヘモグロビン量は減少し、MR信号強度はかえって上昇する。fMRI実験では、このような信号変化を画像化することで脳活動を評価している。BOLD信号は、原理上、脳血流量(CBF)、脳血液量(CBV)、脳酸素代謝量(CMRO2)などの複数の生理学的パラメータに依存する。また撮像シーケンスやMRI装置の磁場強度によって信号の起源となる毛細血管床や細静脈の関与の様式が異なるなど、信号の生成メカニズムは複雑である。fMRIを実験に有効に活用し、その結果を正しく解釈するためには、fMRI原理についての理解が不可欠である。本講演では、BOLD fMRIの生理学的・物理学的メカニズムについてできるだけ分かりやすく解説したい。
著者
福田 恵子
出版者
公益社団法人 日本生体医工学会
雑誌
生体医工学 (ISSN:1347443X)
巻号頁・発行日
vol.Annual60, no.Abstract, pp.213_1, 2022 (Released:2022-12-01)

近赤外光(NIRS:near-infrared spectroscopy)による脳機能計測において、皮膚血流を抑制するためのアルゴリズムとして深さ選択性フィルタが提案されている(1)。深さ選択性フィルタは、光強度変化が生じる要因が、生体組織内で血液量変化が生じる領域を皮膚血液量変化が生じる表層と脳血液量変化が生じる深層の2層のみと仮定して、生体の光学特性をモデル化して3次元解を求め、深層信号のみを抽出して光トポグラフィを再構築する方法である。本手法の適用時には表層信号の変化を選択的に検出するために光の照射・受光間距離の短い(SSD)信号を取得して補正に使用する。しかしながら、表層信号の抑制が過剰に作用し、対象信号が減衰する場合が存在する。この問題の解決ために、モデル化時の解析ボクセルの配置をシミュレーションにより検討した。表層に配置する解析ボクセルについてSSD信号の検出点直下(深さ2㎜)のボクセルを除外することにより、深層信号を減衰の弊害を低減できることを確認した。【参考文献】(1)藤井麻美子他,生体医工学,48(4)pp.383-395,2010.
著者
鈴木 佳代子 関 和則 半田 康延
出版者
公益社団法人 日本生体医工学会
雑誌
生体医工学 (ISSN:1347443X)
巻号頁・発行日
vol.47, no.2, pp.172-175, 2009-04-10 (Released:2009-09-09)
参考文献数
11
被引用文献数
2

Damage of central nervous system caused by a stroke or spinal cord injury usually brings about motor paralysis and increase of muscle tone, spasticity. Excessive spasticity disturbs smooth and coordinated voluntary movement. In this study, we investigated the change of motion parameters during walking in the spastic paraplegic patients and hemiparetic stroke patients before and after application of therapeutic electrical stimulation (ES) . Five spastic paraplegics and seven spastic hemiparetics participated in this study. Eight were male and mean age was 46.3 ± 13.8 (16∼61) years. With regard to the stroke patients, all had left hemiparesis. Stimulation parameters were pulse width of 0.3 msec and frequency of 20 Hz. For the spastic paraplegic patients, stimulation was given to right and left leg alternately during 15 min with 10 s on and 5 s off interval. For the spastic hemiparetic patients, stimulation was only given to the side of paralysis with same duration and interval as the paraplegics. The data of more-spastic side of paraplegics and paralyzed side of hemiparetics were treated as one group (severe side). As for severe side, mean motion range of knee joint was significantly increased after ES (p < 0.05) . Mean motion range of hip joint showed a tendency to increase after stimulation (p < 0.1). Physiological and kinesiological mechanism on the effect of ES providing the change of some motion parameters is complicated. Usually, therapeutic ES for a muscle brings about spasticity inhibition of the antagonist muscle and facilitation of the target muscle. In the present study, ES for rectus muscle possibly suppressed the tone of hamstrings and elicited voluntary action of rectus. Hamstrings have actions as a knee flexor and a hip extensor. Consequently, the motion range of knee and hip joint may have been easily expanded during walking. The results in the present study suggest ES during 15 min can improve gait performance.
著者
三村 祐輝 阿部 光 齊藤 直 杉本 俊之 高橋 龍尚 柳田 裕隆
出版者
公益社団法人 日本生体医工学会
雑誌
生体医工学 (ISSN:1347443X)
巻号頁・発行日
vol.60, no.1, pp.25-31, 2022-03-10 (Released:2022-05-20)
参考文献数
30

In ultrasound systems, there is a trade-off between image quality and the number of transducers (elements) placed in the array probe, and to achieve a high resolution, the array probe must be created with additional elements. In 3D/4D echo, a significant number of elements are required compared to 2D echo, because imaging is performed using a two-dimensional array probe. As a result, 3D/4D echo inevitably has the problem of increasing equipment costs. To solve this problem, it is necessary to develop a method to reconstruct images with higher resolution using fewer elements than conventional imaging methods. The L1-norm minimization method has attracted much attention in recent years because of its ability to reconstruct high-resolution images even from incomplete data. In this study, we investigated whether high quality images can be reconstructed by minimizing the L1 norm for an object with an orientation, height, and depth of the imaging area (3D object). We also used image quality evaluation methods (MSE: Mean Squared Error, PSNR: Peak Signal to Noise Ratio, and SSIM: Structural SIMilarity) to quantitatively evaluate the obtained images. The results confirmed that L1-norm minimization is capable of reconstructing high-quality images with high evaluation values in all image quality evaluation methods compared to conventional methods.
著者
島崎 拓則 原 晋介 奥畑 宏之 中村 肇 河端 隆志
出版者
公益社団法人 日本生体医工学会
雑誌
生体医工学 (ISSN:1347443X)
巻号頁・発行日
vol.54, no.5, pp.225-235, 2016-10-10 (Released:2017-01-14)
参考文献数
23
被引用文献数
2

Monitoring heart rate (HR) during exercise can be used not only for early detection of a change in physical condition but also as an indication of the exercise training condition. Photoplethysmography (PPG) is a simple and non-invasive method for HR sensing, but its use during exercise is difficult, since the PPG output is contaminated with motion artifact (MA). Especially for vigorous exercise, MA has the same frequency component as that of blood volume pulses (BVPs) in the PPG output, and no linear MA cancellation technique such as band pass filtering (BPF) can work effectively. This paper proposes a PPG-based MA canceling HR sensor. It is equipped with two sensors ; one is a normal PPG sensor with a light emitting diode (LED)/photo detector (PD) that contacts the skin to detect BVPs andMA, andthe other is an MA sensor with a LED/PD that does not contact the skin to detect only MA. Applying the outputs from the two sensors to an adaptive filter, the BVPs can be obtained easily. We evaluated the performance of the proposed HR sensor in ten subjects who performeda series of resting, walking, running andjumping. The results revealedthat the proposedHR sensor, together with an outlier rejection method, achieved root mean square errors (RMSEs) of 7.1 bpm, 6.4 bpm and6.1 bpm for walking, running andjumping, respectively, when using a Holter monitor as the reference. These results imply a reduction of RMSE by a maximum of 83% compared to no MA cancellation.
著者
萬谷 惇 中川 誠司 小谷 賢太郎 堀井 健
出版者
公益社団法人 日本生体医工学会
雑誌
生体医工学 (ISSN:1347443X)
巻号頁・発行日
vol.45, no.1, pp.114-120, 2007 (Released:2008-06-05)
参考文献数
14

Although several studies have reported that the rise-time of sound stimulus affects on auditory evoked magnetic fields, effects of each parameter which vary in connection with rise-time—whole energy, rising-speed (dL/dt), spectrum—have not been clarified. In this study, N1m amplitudes and latencies were examined using noise-bursts with varying rise-time and constant energy or rising-speed. The results showed that N1m increased in amplitude and decreased in latency as rise-time increased (i.e, energy increased) under the rising-speed-constant condition. In contrast, N1m amplitudes and latencies did not vary significantly as rise-time increased (i.e., rising-speed decreased) under the energy-constant condition. These results indicate that sound energy has greater effects on N1m amplitude and latency than rising-speed.
著者
成瀬 康
出版者
公益社団法人 日本生体医工学会
雑誌
生体医工学 (ISSN:1347443X)
巻号頁・発行日
vol.Annual58, no.Abstract, pp.130, 2020 (Released:2020-08-05)

我々は,いつでもどこでも計測が可能なウェアラブル脳波計の開発を行っている.これを利用することで,病院や研究室以外での脳波計測が容易となってきている.これにより,脳波を使った応用の範囲が広がっている.我々は,無意識や言語化が困難な情報を可視化することで初めて実現できるシステムの開発を目指した研究を行っている.例えば,音の違いに反応する事象関連電位であるミスマッチ陰性電位を利用したニューロフィードバックトレーニングにより,日本人が聞き分けることが苦手な「right」と「light」の違いが認識できるようになることを明らかにした.また,英語を聞いている時の脳波を計測し,N400に相当する事象関連電位を抽出することで,その人の英語の能力の推定が可能であることも明らかにした.さらに,テレビゲームを行っているときの脳波を計測し,エラーをしたときに発生する事象関連電位であるエラー関連陰性電位を抽出することで,ゲームへの没入度の推定ができる可能性が示唆された.このように,脳波を利用することで無意識および言語化が困難な情報を取り出すことができる可能性が示唆された.
著者
平田 智之 井上 敬介 古川 大介 佐伯 壮一 塚原 義人
出版者
公益社団法人 日本生体医工学会
雑誌
生体医工学 (ISSN:1347443X)
巻号頁・発行日
vol.59, no.6, pp.169-173, 2021-12-10 (Released:2022-02-05)
参考文献数
10

In recent years, the regenerative treatment of osteoarthritis (OA) by transplantation of autologous cultured cartilage has been developed, but biomechanical diagnostic evaluation of cartilage has not yet been performed in the follow-up after transplantation as well as typical OA diagnostic treatment. In this study, we constructed an Optical Coherence Doppler Velocigraphy (OCDV) system based on low coherence interferometer (OCT) and a compression tester as loading device, which can provide micro-tomographic visualization of tissue deformation and joint fluid flow inside cartilage tissue. The constructed system was applied to not only the normal sample of porcine knee cartilage but also the simulated degenerative one by collagenase enzyme treatment for 2 hours. As experimental results, during compression period, the both cartilage samples in the middle layer were observed to move toward surface, generating the compressive strain further in superficial layer. Doppler velocity of the degenerated cartilage was detected to be about 50µm/sec in the middle layer, which was twice as high as that of normal cartilage. Just after stress relaxation, Doppler velocity decreased immediately to be less than 5µm/sec in the normal cartilage, whereas are keeping about 10µm/sec in the degenerated one. These are considered to be due to the decrease in biomechanical properties, i. e. visco-elasticity, of degenerated cartilage. In conclusions, the proposed method can discriminate quantitatively between normal and OA cartilage from the spatiotemporal change of the detected Doppler velocity, in the virtue of revealing microscopic tissue deformation and joint fluid flow with high spatio-temporal resolution, therefore OCDV has an effective potential as a real-time diagnostic imaging system.
著者
中尾 善明 高田橋 篤史 鎗田 勝 藤元 登四郎 田村 俊世
出版者
公益社団法人 日本生体医工学会
雑誌
生体医工学 (ISSN:1347443X)
巻号頁・発行日
vol.49, no.6, pp.805-814, 2011-12-10 (Released:2012-04-10)
参考文献数
19

Remarkable progress in cognitive neuroscience has revealed the involvement of the prefrontal cortex and the orbitofrontal cortex in human working memory, but the orbitofrontal cortex is still one of the least understood regions in the human brain. To elucidate the contribution of the orbitofrontal cortex to human working memory, we studied EEG P300 activity in n-back task. We elicited early P3 around 300 ms and late P3 around 360 ms of P300 components in n-back ERP. The amplitudes of the respective peaks changed depending on the working memory load (0-back, 1-back, 2-back, 3-back). We used source analysis to evaluate the orbitofrontal cortex in P3 components. A source model was constructed with the sources seeded from fMRI meta-analysis of n-back task and additional sources in the orbitofrontal cortex and the visual cortex estimated with P100 and late P3 components in the n-back ERP. This source model had more than 99% of GOF (goodness of fit) in n-back ERP. It gave us an insight of brain activity at the positions where sources existed. Early P3 was mainly produced by the dorsolateral prefrontal cortex, the ventrolateral prefrontal cortex, the inferior parietal lobule, the medial posterior parietal and the visual cortex. Late P3 was mainly produced by the medial premotor, the lateral premotor, the frontal pole and the orbitofrontal cortex. The contribution of the frontal pole and the orbitofrontal cortex had peaks around 390 ms which were later than late P3 component. In this study, the method to evaluate the orbitofrontal cortex activity in n-back ERP was provided. Our results elicited the involvement of the orbitofrontal cortex in late P3 component of n-back ERP.
著者
岡 久雄 福原 真一
出版者
公益社団法人 日本生体医工学会
雑誌
生体医工学 (ISSN:1347443X)
巻号頁・発行日
vol.57, pp.S188_1, 2019

<p>スポーツ等での運動能力(筋トレ効果)は最大筋力や繰返し回数,最高タイムなどで評価されることが多く,直接的には対象筋の収縮能力を評価していないことが多い。著者らは表面筋電図:EMGと,筋の収縮に伴うせん断応力波の伝搬振動を,皮膚表面に置いた変位計で測定する筋音図:MMGを同時計測できるMMG/EMGハイブリッドセンサを用いて,上腕二頭筋の等尺性収縮を行った際のMMGとEMGを測定した。被験者は20代健常成人10名,起座位で右肘関節を60度に保ち,センサを右上腕二頭筋腹上に貼付した。等尺性収縮は10%から100% MVCまで10%ずつ上昇させ,収縮時のMMG/EMG時間波形をそれぞれ二乗和した値を求めた。MMGは10~30%MVC:緩やかに増加,30~70%MVC:やや急激に増加,70%MVC以上:減少した。50%MVCの値で規格化し,%MVCの区間を区切って1次式近似(数値は傾き:相関係数r<sup>2</sup>が0.8以上)を行った(表)。本結果は運動単位の動員や発火頻度をもとに上腕二頭筋の等尺性収縮過程を説明した報告を支持するものであった。今後は本センサシステムを動的な運動計測へと展開したい。</p>
著者
佐々木 紀幸 香川 正幸 鈴村 和季 松井 岳巳
出版者
公益社団法人 日本生体医工学会
雑誌
生体医工学 (ISSN:1347443X)
巻号頁・発行日
vol.53, no.4, pp.209-216, 2015-08-10 (Released:2015-12-10)
参考文献数
15
被引用文献数
1

Disturbed sleep has become more common in recent years. To improve the quality of sleep, undergoing sleep observation has gained interest in an attempt to resolve possible problems. Additionally, the classification of real-time sleep states without interference is needed in nursing and medical settings. In this paper, we discuss a non-restrictive and non-contact method for estimating real-time sleep stages and report its potential applications and problems. The system we used measured body movements and respiratory signals of a person while sleeping using dual 24-GHz microwave radars placed underneath the mattress. We first determined a body movement index to identify wake and sleep, and fluctuation indices of respiratory intervals to indicate sleep stages. The data of movements and respiratory signals derived from 11 healthy university students were used for feature selection and training of the classification model parameters. For identifying wake and sleep, the rate of agreement between the body movement index and the result using the R & K method as reference was 83.5±6.3%. Five-minute standard deviation, a fluctuation index of respiratory intervals, had a high degree of contribution and showed a significant difference (p<0.001) among three sleep stages (REM, LIGHT, DEEP). Th e degree of contribution of the 5-min fractal dimension of respiratory intervals, a fluctuation index, was not as high as expected but showed a significant difference (p<0.05) between REM and DEEP. For validation, we applied canonical discriminant analysis to classify wake or sleep and to estimate the three sleep stages in two additional university students. The accuracy was 79.3% and 59.5% for classification of wake/sleep and 71.9% and 64.0% for estimation of three sleep stages. The novelty of this study includes measurements of body movements and respiration-induced body surface movements withh ighsensitivities using microwave radars, and systematic analysis of the indices of body movement and respiratory interval. The method allows easy measurement of sleep stages in nursing care and home settings and may be employed to increase the quality of sleep. Although we successfully estimated three sleep stages, the method requires further study to determine the five stages of sleep.
著者
朔 啓太
出版者
公益社団法人 日本生体医工学会
雑誌
生体医工学 (ISSN:1347443X)
巻号頁・発行日
vol.59, pp.154, 2021

<p>「アイディアを予算化し、実現すること」は研究者における定義の一つである。医工学分野では実現とは医療につながる機器を創出することであり、医療機器創出には、ものを作る技術とともに、実用化を目指した産学連携活動が必須である。発表者は、所謂ビッグボスのもと、豊富な研究資金や産学連携活動が当たり前として存在する環境でキャリアをスタートしたが、自身が主任研究者(PI)をつとめるようになると、企業導出の難しさを実感するようになった。研究コンセプトが独創的かつ可能性にあふれていても、無名で業績がない若手に投資を積極的にしたがる人は少ない。挑戦を恐れる日本社会などという安易な社会批判に帰着する問題ではなく、若手だからこそ、大胆なコンセプトを実現する確度を適切に主張する必要がある。発表者は幸いにも、さまざまな産学連携活動に携わることができているが、もっとも重要であったアクションは、臨床的にインパクトのある論文を積み重ね、学会などの場で自身の認知を医師だけでなく企業の方々に増やしたことである。長期的視点で物事に取り組める点で若手であることはそれ自体が武器である。一方、期待値につながる「その人本人の」研究文脈がコラボレーション開始には重要である。</p>
著者
上野 太郎 伊藤 誠 小川 潤 青山 敦
出版者
公益社団法人 日本生体医工学会
雑誌
生体医工学 (ISSN:1347443X)
巻号頁・発行日
vol.56, pp.S310, 2018

<p>前庭感覚系は, 体の傾きを察知するのに重要な役割を担っており,視覚系を始めとする複数の感覚系から情報を受け取っている.しかしながら, 前庭感覚系を調べる脳計測実験を設計するのは技術的に難しく,前庭感覚情報と視覚情報の相互作用については不明な点が多い.そこで本研究では,前庭感覚入力を操作するために反転台,前庭感覚入力の手掛かりを視覚的に与えないために Virtual Reality (VR) Display を使用し,反転台によって実験協力者の体勢を変えた上で VR Display を介した落下映像に対する脳波の計測を行った.事象関連電位解析において,視覚的な落下方向に関わらず, 倒立状態では直立状態と比較して落下開始後 100-200 ms から 視覚活動の減衰が確認された. また,Granger Causality 解析において,頭頂前庭領域から視覚領域への有意なコネクションが確認された.以上の結果により,異常な前庭感覚情報によって視覚活動が抑制され,視覚処理の比較的早い段階から視覚と前庭感覚の相互作用が始まることが示唆された.</p>