著者
伊藤 清 川島 実 荒井 義人 高橋 満博 村上 宏次 野部 達夫
出版者
日本建築学会
雑誌
日本建築学会環境系論文集 (ISSN:13480685)
巻号頁・発行日
vol.81, no.723, pp.447-455, 2016
被引用文献数
1

&nbsp;Energy conservation technology has been in high demand in relation to efforts to realize (net) zero-energy buildings (ZEBs). Ceiling radiant cooling panel systems represent a key energy-conservation technology which can yield high efficiency, since it uses moderately cold water (16-18&deg;C), offers integration with other energy-efficient strategies, such as indirect evaporative cooling or ground source heat pumps, and does not require energy to propel a fan to remove the cooling load. Furthermore, a radiant ceiling cooling panel system provides greater comfort to occupants because it does not produce a draught. Therefore, ceiling radiant cooling panel systems can offer both reductions in cooling energy consumption and a comfortable environment for occupants.<br>&nbsp;However, there are several problems with applying a ceiling radiant cooling system in Japan. Firstly, there is limited data about the cooling performance of such systems because few have been constructed in Japan. For this reason, it is important to determine the cooling performance of radiant ceiling panels. Secondly, radiant ceiling panels have limited cooling performance, so it is necessary to consider a special system to remove the perimeter load. Thirdly, an outdoor air-conditioning system is needed to provide outdoor air to occupants. The objective of this paper is to present an outline of the proposed system, results of the thermal performance tests in an experimental facility, and the operational performance in a building to which the proposed system is applied.<br>&nbsp;The proposed system consists of ceiling radiant cooling panels, perimeter chilled beams, and an outdoor-air supply system. The ceiling radiant cooling panels remove the interior cooling load. The perimeter chilled beams remove the perimeter cooling load. The outdoor-air supply system has a personal floor diffuser, a perimeter linear diffuser and a return-air inlet near the window top. The return-air inlet removes the hot air from the window to remove the perimeter load efficiently.<br>&nbsp;An experimental facility for the proposed system was constructed, and thermal performance tests were performed. The results show a vertical temperature differential of less than 0.5&deg;C, and the perimeter chilled beam can remove the peak summer cooling load appropriately. The cooling capacity of the ceiling radiant cooling panels and perimeter chilled beams are approximately 80 W/m<sup>2</sup> and 120 W/m<sup>2</sup> respectively under conditions whereby the difference in temperature between the water input and output is 9.0&deg;C.<br>&nbsp;Measurement of the system was performed in the actual building to which the system was applied. The results show that the ceiling radiant cooling panels and chilled beams can be controlled to remove varying cooling loads. The cooling capacity of the ceiling radiant cooling panels and chilled beams in the actual building proved almost equal to the experimental data. Thus, it is demonstrated that the proposed system can remove the cooling load as expected.
著者
伊藤 清 川島 実 荒井 義人 高橋 満博 村上 宏次 野部 達夫
出版者
日本建築学会
雑誌
日本建築学会環境系論文集 (ISSN:13480685)
巻号頁・発行日
vol.81, no.723, pp.447-455, 2016
被引用文献数
1

Energy conservation technology has been in high demand in relation to efforts to realize (net) zero-energy buildings (ZEBs). Ceiling radiant cooling panel systems represent a key energy-conservation technology which can yield high efficiency, since it uses moderately cold water (1618°C), offers integration with other energy-efficient strategies, such as indirect evaporative cooling or ground source heat pumps, and does not require energy to propel a fan to remove the cooling load. Furthermore, a radiant ceiling cooling panel system provides greater comfort to occupants because it does not produce a draught. Therefore, ceiling radiant cooling panel systems can offer both reductions in cooling energy consumption and a comfortable environment for occupants. However, there are several problems with applying a ceiling radiant cooling system in Japan. Firstly, there is limited data about the cooling performance of such systems because few have been constructed in Japan. For this reason, it is important to determine the cooling performance of radiant ceiling panels. Secondly, radiant ceiling panels have limited cooling performance, so it is necessary to consider a special system to remove the perimeter load. Thirdly, an outdoor air-conditioning system is needed to provide outdoor air to occupants. The objective of this paper is to present an outline of the proposed system, results of the thermal performance tests in an experimental facility, and the operational performance in a building to which the proposed system is applied. The proposed system consists of ceiling radiant cooling panels, perimeter chilled beams, and an outdoor-air supply system. The ceiling radiant cooling panels remove the interior cooling load. The perimeter chilled beams remove the perimeter cooling load. The outdoor-air supply system has a personal floor diffuser, a perimeter linear diffuser and a return-air inlet near the window top. The return-air inlet removes the hot air from the window to remove the perimeter load efficiently. An experimental facility for the proposed system was constructed, and thermal performance tests were performed. The results show a vertical temperature differential of less than 0.5°C, and the perimeter chilled beam can remove the peak summer cooling load appropriately. The cooling capacity of the ceiling radiant cooling panels and perimeter chilled beams are approximately 80 W/m2 and 120 W/m2 respectively under conditions whereby the difference in temperature between the water input and output is 9.0°C. Measurement of the system was performed in the actual building to which the system was applied. The results show that the ceiling radiant cooling panels and chilled beams can be controlled to remove varying cooling loads. The cooling capacity of the ceiling radiant cooling panels and chilled beams in the actual building proved almost equal to the experimental data. Thus, it is demonstrated that the proposed system can remove the cooling load as expected.
著者
若林 宗平 ジャベル ニザル 野口 伸
出版者
農業食料工学会
雑誌
農業機械學會誌 (ISSN:02852543)
巻号頁・発行日
vol.72, no.3, pp.268-275, 2010-05-01
参考文献数
9

トラクタ機関として二燃料機関を用いる場合,軽油消費量を削減しつつ燃焼効率を向上させるには,バイオガスの供給を機関負荷に応じて制御する必要がある。本研究では,二燃料機関へのバイオガス供給の最適化を行い,目的関数に応じたバイオガスの供給マップを作成した。自作した電子制御ユニット(Electric Control Unit ; ECU)を用いてバイオガス供給の制御を行い,最適化したトラクタ用ディーゼル機関の出力性能,排気性能の評価を行った。<BR>出力性能試験の結果,機関の最大出力,最大トルクに変化は見られず,軽油単味運転時と同程度であった。ISO計測基準8178-4に基づいて負荷条件を平均化した排出ガス特性を検討した結果,最適化後の二燃料機関の排気性能は所期の目的関数に見合った結果となり,CO排出量の改善がみられた。また,軽油の消費減少量,正味熱消費率についてもバイオガス最適化の効果が認められ,低負荷時の燃焼効率は改善された。最適化した機関を用いてほ場作業のシミュレーションを行った結果,バイオガス供給マップにより想定される機関性能が得られた。
著者
若林 宗平 ジャベル ニザル 野口 伸
出版者
The Japanese Society of Agricultural Machinery and Food Engineers
雑誌
農業機械學會誌 (ISSN:02852543)
巻号頁・発行日
vol.72, no.3, pp.268-275, 2010-05-01

トラクタ機関として二燃料機関を用いる場合,軽油消費量を削減しつつ燃焼効率を向上させるには,バイオガスの供給を機関負荷に応じて制御する必要がある。本研究では,二燃料機関へのバイオガス供給の最適化を行い,目的関数に応じたバイオガスの供給マップを作成した。自作した電子制御ユニット(Electric Control Unit ; ECU)を用いてバイオガス供給の制御を行い,最適化したトラクタ用ディーゼル機関の出力性能,排気性能の評価を行った。<BR>出力性能試験の結果,機関の最大出力,最大トルクに変化は見られず,軽油単味運転時と同程度であった。ISO計測基準8178-4に基づいて負荷条件を平均化した排出ガス特性を検討した結果,最適化後の二燃料機関の排気性能は所期の目的関数に見合った結果となり,CO排出量の改善がみられた。また,軽油の消費減少量,正味熱消費率についてもバイオガス最適化の効果が認められ,低負荷時の燃焼効率は改善された。最適化した機関を用いてほ場作業のシミュレーションを行った結果,バイオガス供給マップにより想定される機関性能が得られた。
著者
ジャベル ニザル 塚本 隆行 野口 伸
出版者
農業食料工学会
雑誌
農業機械學會誌 (ISSN:02852543)
巻号頁・発行日
vol.70, no.3, pp.97-105, 2008-05-01
参考文献数
19
被引用文献数
2

環境負荷低減を目的として, バイオガス・軽油二燃料機関による農用トラクタの開発を行った。本研究では, バイオガス・軽油二燃料トラクタ機関について, バイオガス供給量を自動制御するバイオガス供給アルゴリズムの開発を目的とした。<br>二燃料運転によるディーゼル機関の基本性能について, 特にバイオガスと軽油の熱量換算の燃料消費率 (BSHC) 及び燃料代替率の検討を行った。二燃料運転の基本性能を把握した後, 吸気管内圧力 (MAP) を機関負荷推定のパラメータとして, バイオガス供給制御アルゴリズムの試作と性能試験を行った。試験の結果, 試作アルゴリズムは安定して機関回転数と負荷に応じてバイオガス供給量を制御できた。
出版者
日経BP社
雑誌
日経ものづくり (ISSN:13492772)
巻号頁・発行日
no.740, pp.136-138, 2016-05

基調講演に続き4日間にわたって行われたセッションでは、利用分野や装置メーカーごとに20弱のトラックが設けられ、各社が自社の技術や活用事例を紹介した。中でもとりわけ大きな注目を集めていたのが米Carbon社だ*4。 Carbon社は、2015年3月に「CLIP」(Continuous L…
著者
ジャベル ニザル 野口 伸
出版者
The Japanese Society of Agricultural Machinery and Food Engineers
雑誌
農業機械學會誌 (ISSN:02852543)
巻号頁・発行日
vol.69, no.1, pp.89-98, 2007-01-01
被引用文献数
4

農産物残渣物から得られるバイオガスを, 脱硫・高濃度化し農用車両の燃料へ適用することは, これまでの電気熱源利用同様, 有益な技術である。<br>適用に当たって, 農用車両に用いられるディーゼル機関の点火機構は, 排ガス性能へ直接影響することから, 十分に文献調査した。天然ガスやバイオガスなどのメタンを軽油とともにディーゼル機関の燃料とする二燃料運転では, NO<sub>x</sub>と黒煙を減少させるが, 高負荷ノックを起こし, 低負荷では失火を起こすことが明らかにされている。これら問題の解決方法は世界中で研究されており, 一部実用化に至っているものもあるが, 未だ様々な試みが行われている。
著者
Ejeatuluchukwu OBI Orish Ebere ORISAKWE Charles OKAFOR Anthony IGWEBE Joy EBENEBE Onyenmechi Johnson AFONNE Francis IFEDIATA Basu NILS Jerome NRIAGU
出版者
産業医科大学学会
雑誌
Journal of UOEH (ISSN:0387821X)
巻号頁・発行日
vol.36, no.3, pp.159-170, 2014
被引用文献数
15

この研究は,ナイジェリアにおいて,母体および臍帯血の血中鉛濃度(BLL)を測定し,他の地域と比較することを目的とする.我々は,母親の血液および臍帯血のBLLと,新生児の人類学的計測値との関連性の調査を行った.ナイジェリア南東部ンネウィの別の3病院で出産した119人の女性から採取した,臍帯血および母親の血液サンプルを用いてBLLを測定した(誘導結合プラズマ質量分析法(ICP-MS)を使用).新生児の人類学的計測(頭囲・腹囲・出生体重・出生身長・頭臀長)を行った.母親の血液サンプルの10.9%,臍帯血サンプルの3.4%から,10 μg/<i>l</i>より多い鉛が検出された.母体のBLLは6.19±2.77 μg/d<i>l</i> (平均±標準偏差),臍帯血BLLは4.75±2.59 μg/d<i>l</i> (平均±標準偏差)であった.臍帯血BLLと頭臀長の明確な関連性(R = 0.204,<i>P</i> = 0.026)を除けば,子どもたちの人類学的計測値と,母親の血液および臍帯血BLLには有意な関連性は見られなかった.