著者
堀田正敦 編
出版者
巻号頁・発行日
vol.[262],
著者
大石 正夫 西塚 憲次 本山 まり子 小川 武
出版者
Japanese Society of Chemotherapy
雑誌
CHEMOTHERAPY (ISSN:00093165)
巻号頁・発行日
vol.23, no.5, pp.2040-2044, 1975
被引用文献数
2

The results of laboratory and clinical experiments for ophthalmic use of fosfomycin (FOM) were summarized as follows.<BR>1. The minimum growth inhibitory concentrations of FOM against organisms caused ocular infections were 25-50, μg/ml for KOCH-WEEKS <I>bacillus</I>, 1.56-6.25, μg/ml for MORAX-AXENFELD <I>diplobacillus</I>, 6.25->100gg/ml for <I>Diplo. pneumoniae</I>, >100, μg/ml for <I>Strept. viridans</I>, 6.25-25μg/ml for <I>Strept. hemolyticus</I>, >100, μg/ml for Cory. <I>diphtheriae</I>, 6.25, μg/ml for <I>N. gonorrhoeae</I> and 1.56, μg/ml for <I>Staph. aureus</I> FDA 209 P.<BR>2. The sensitivity of <I>Ps. aeruginosa</I> and <I>Staph. aureus</I> isolated from eye patients : The distribution of the sensitivity for 11 strains of <I>Ps. aeruginosa</I> was in the range of 3.13->100μg/ml, 6strains (54.9%) were inhibited under 12.5μg/ml.<BR>Twelve strains of <I>Staph. aureus</I> were sensitive in 1.56->100μg/ml, 6 strains (50%) were in 6.25μg/ml.<BR>3. Serum level : After oral administration of 500mg FOM-Ca in a single dose, the peak level was attained 2 hours (4. 33 μg/ml), then decreased gradually up to 8 hours (1.0μg/ml). <BR>4. Ocular penetration : <BR>Ocular penetrations after oral application of 50mg/kg FOM-Ca were examined with rabbit eye. The aqueous humor levels revealed from 1/4 to 6 hours, the peak level was 1 hour (14.μg/ml). The high ocular tissue concentrations were recognized in both outer and inner parts of the eye at 2 hours after oral administration.<BR>5. Clinical effects : Twenty-one cases of ocular infections, such as external hordeolum, lid abscess, acute and chronic dacryocystitis, tenonitis, corneal ulcer, infection of socket and perforating injury, were treated with oral administration of FOM-Ca 250mg or 500mg 4 times daily. Good clinical effects were obtained in 13 cases.<BR>6. Side effects : One case of diarrhoea and 2 cases of anorexia were observed, but no cessation of application was needed. No other severe side effects were noticed.
出版者
主婦と生活社
巻号頁・発行日
1981

1 0 0 0 OA 御仕置例類集

出版者
巻号頁・発行日
vol.[51] 〔第三輯〕 二十八 上 女之部 博奕いたし又者携候類・博奕其外賭事相催候を不存類・隠売女之類・火附盗賊之類・,
著者
朱 藝
出版者
日本文化人類学会
雑誌
日本文化人類学会研究大会発表要旨集 日本文化人類学会第52回研究大会 (ISSN:21897964)
巻号頁・発行日
pp.176, 2018 (Released:2018-05-22)

本分科会は、これまで交流の少なかった文化/社会人類学的なビジネスを対象とする研究と、ビジネス分野におけるエスノグラフィ実践とが相互に関わるための「コンタクト・ゾーン」を生み出すことを目的としている。主に、海外における日系企業や組織研究から見る人類学的アプローチの可能性と限界、ビジネスエスノグラファーから見るウェブデザインにおける文化的差違、企業へのエスノグラフィ導入・適合プロセスを議論する。
著者
鍛冶 美幸
出版者
京都大学大学院教育学研究科
雑誌
京都大学大学院教育学研究科紀要 (ISSN:13452142)
巻号頁・発行日
vol.64, pp.291-302, 2018-03-30

従来の認知行動療法では、身体症状や問題行動を言語化して説明することを通して、身体は客体化されてきた。また生理的なアプローチや行動の修正に取り組む身体は、問題を解決するための道具として対象化されてきた。しかし第三世代の認知行動療法では、マインドフルネスという仏教思想にもとづく心身観を取り入れ、ありのままの身体を客観的に観察し言語化して認識する方法が用いられた。そこには身体の客体化や対象化から離れた、身心一如にもとづく日本古来の心身観や身体鍛錬との関連が認められる。症状や問題行動の苦悩も含め、環境や自分自身のすべてをつながりのなかに在るものとして受け入れるという仏教思想の「縁起」は、この概念を理解するために意味を持つ。こうした視座に立ち、心と不可分の、自らの生の根源としての身体と向き合い身体技法に取り組むことは、認知行動療法の身体性をめぐる重要なパラダイムといえるのではないだろうか。
著者
小山 征哉 小倉 陽子 勝海 一郎
出版者
特定非営利活動法人 日本歯科保存学会
雑誌
日本歯科保存学雑誌 (ISSN:03872343)
巻号頁・発行日
vol.50, no.6, pp.688-697, 2007
参考文献数
41
被引用文献数
3

この研究の目的は,エンジン用の根管拡大形成器具で根管形成を行ったことを想定したテーパーが6/100の樹脂性湾曲根管模型に,材質,サイズが異なる8種のスプレダーを用い側方加圧充填法による根管充填を行い,湾曲根管におけるスプレダーの種類によるガッタパーチャポイントの圧接の違いを評価することにある.すなわちDentalEZの2種のステンレススチール製スプレダー(Star Dental D11T〔S-D11Tと略〕,Star Dental D11〔S-D11と略〕,と,Roekoの4種のニッケルチタン製スプレダー(NiTi #15〔R-15と略〕,NiTi #25〔R-25と略〕,NiTi #35〔R-35と略〕,NiTi D11T〔R-D11Tと略〕),Brasselerの2種のニッケルチタン製スプレダー(Navi-flex NT D11T〔B-D11Tと略〕,Naviflex NT 4SP〔B-4SPと略〕)を用い,側方加圧充填法による根管充填を行った.圧接状態の評価は,マイクロフォーカスX線CT装置により撮影された根尖から1,2,3,4,5,6,7mmの各位置の根管断面に占めるガッタパーチャポイントの割合(ガッタパーチャ充塞率)を求めることにより,各スプレダーの圧接状態の分析を行い,以下の結論を得た.1〜7mmの全断層像におけるガッタパーチャ充塞率の平均は,S-D11Tスプレダーが93.9%と最も高く,次いでB-D11Tが93.7%,S-D11が86.1%,R-25が85.3%,R-D11Tが85.2%,R-15が82.9%,R-35が76.8%,B-4SPが76.2%の順に低下し,根管の封鎖は不十分となった.なおスプレダーの種類が,ガッタパーチャ充塞率に及ぼす影響については高度に有意であることが認められた.1〜7mmの各断層位置における断層像のガッタパーチャ充塞率は,S-D11Tが各断層位置で90.8%以上の,またB-D11Tが90.5%以上の高い値を示した.これに対しR-35は断層位置6mmで65.9%,B-4SPは4mmで69.4%の低い値を示し,充塞率が船底型に大きく落ち込む現象が認められた.なお,R-25,R-15,R-D11T,S-D11でも,充塞率が局所的に低下する落ち込み現象がみられた.以上の結果より,湾曲根管におけるスプレダーの選択に際しては,材質によるしなやかさよりもスプレダーの径やテーパーによる根管への挿入性や圧接性を優先し,選択すべきであることがわかった.
著者
Masaki Hideyuki
出版者
Kinki University Medical Association
雑誌
ACTA MEDICA KINKI UNIVERSITY = The Kinki University Medical Association (ISSN:03866092)
巻号頁・発行日
vol.38, no.2, pp.101-109, 2013-12-01

[Abstract] Xenograft rejection caused by xenoreactive T cells is a major obstacle to xenotransplantation. To analyze anti-xeno T-cell responses, xeno-reactive T-cell clones derived from C57BL/6 (B6) mice immunized with Wistar Furth (WF) rat cells were established. All CD8 clones proliferated in response to WF rat thymocytes even in the absence of B6 mouse splenocytes as antigen-presenting cells, indicating that they responded to xeno-antigen via the direct recognition pathway. In contrast, all CD4 clones proliferated against WF cells only when syngeneic splenocytes were added to the cultures, indicating that they responded via the indirect recognition pathway. All CD8 clones proliferated in response to thymocytes from WF, BB, or PVG.1R8 rats, but not to LEWIS or PVG rats. They also lysed NK-resistant C58NT(D) lymphoma cells of WF rat origin in a dosedependent manner, suggesting specificity for the rat MHC class I RT1C" allele, and their function as cytotoxic T lymphocytes. All CD4 clones proliferated against rat thymocytes of various strains only in the presence of splenocytes from B6 or BALB.B mice, which possess the H-2b haplotype, indicating that they recognize rat xeno-antigens shared between different strains in an H-2"-restricted manner. All CD4 clones secreted predominantly interferon y in response to rat xeno-antigen, suggesting that they possess Thl characteristics. Because all clones are likely to act as effector cells for xenograftrejection, they are expected to be useful for investigating mechanisms of xenograft rejection mediated by cellular immunity, and should be a good source of TcR genes for creating transgenic mice to supply naive xeno-reactive T cells.
著者
勝海 一郎 山崎 孝子 都築 民幸 北村 和夫 石井 隆資 前田 宗宏 小倉 陽子 好士 連太郎 阿川 透久 宮里 尚幸 大島 克郎 大村 朋己 丸山 博吉 木津喜 美香 小山 征哉 遠藤 春江
出版者
特定非営利活動法人 日本歯科保存学会
雑誌
日本歯科保存学雑誌 (ISSN:03872343)
巻号頁・発行日
vol.49, no.6, pp.846-853, 2006
参考文献数
32
被引用文献数
1

On 6 types of Ni-Ti spreader (Roeko NiTi # 15; Roeko NiTi # 25; Roeko NiTi # 35; Roeko NiTi D11T; Brasseler Naviflex NT D11T; Brasseler Naviflex NT 4SP), dimensions were measured under digital microscope, and a load application test was performed in the axial direction of the spreader. The results were as follows: 1. In Roeko NiTi # 15, D<sub>3</sub> was 0.38 mm, D<sub>16</sub> was 0.61 mm, taper was 0.018, and tip angle was 28.9°. Similarly, the above values were 0.32 mm, 0.68 mm, 0.027, and 28.0° respectively in Roeko NiTi # 25. The values were 0.50 mm, 0.70 mm, 0.016, and 32.5° respectively in Roeko NiTi # 35, and the values were 0.37 mm, 0.88 mm, 0.039, and 10.6° respectively in Roeko NiTi D11T. The values were 0.27 mm, 0.77 mm, 0.038, and 29.9° respectively in Brasseler Naviflex NT D11T, and 0.30 mm, 1.06 mm, 0.059, and 35.9° respectively in Brasseler Naviflex NT 4SP. 2. When a load was applied in the axial direction of the spreader, the load was 0.56 kgf in case the portion of 16 mm in length from the tip in Roeko NiTi # 15 was bent at a stroke. When the portion of 5 mm in length from the tip was fixed and the portion of 11 mm in length from the tip was bent at a stroke, the load was 4.32 kgf. The above values were 1.13 kgf and 7.52 kgf respectively in Roeko NiTi # 25, 1.24 kgf and 8.58 kgf in Roeko NiTi # 35, 0.82 kgf and 10.28 kgf in Roeko NiTi D11T, 0.63 kgf and 7.27 kgf in Brasseler Naviflex NT D11t, and 1.02 kgf and 17.61 kgf in Brasseler Naviflex NT 4SP. 3. The Ni-Ti spreader has super-elasticity and is flexible. Thus, it is difficult to apply pressure on it in the axial direction, during lateral condensation. However, this study revealed that sudden bending may be avoided if at least the tip portion of 5 mm in length from the tip is inserted into the root canal.

1 0 0 0 OA 天保撰要類集

出版者
巻号頁・発行日
vol.[43] 第十六 二 御祝儀之部 七,

1 0 0 0 OA 屋敷願吟味帳

出版者
巻号頁・発行日
vol.[41] 文政三辰年 分冊ノ一,
著者
高島 太郎 中島 敦司 山本 将功
出版者
名古屋大学
雑誌
環境システム研究論文集 (ISSN:00277622)
巻号頁・発行日
vol.56, no.1, pp.81-87, 1993-11

自然環境整備事業における短期間で合意に至った事例から, 当事者と行政の合意形成過程における問題構造を明らかにすることを目的に, 関係者に対する事業過程におけるヒアリングと発言の記録から, PCM手法による「問題-原因構造図」作成と発言内容のクラスター分析を行った. その結果, PCM手法では合意形成過程で当事者による「行政への不信」, 「計画案への不満」, 「地域秩序の乱れ」, 「農地景観の悪化」を主問題とする構造が明らかとなった. クラスター分析でも「行政への不信」は独立した分類を得られたことにより, 合意に至る過程では, その払拭が重要で, 会議で合意を得ようとすることに加え, 個別対応による情報収集を積み重ね, 当事者一人一人の意見に耳を傾ける重要性が指摘された.
著者
乾 雅祝 石川 大介 田村 剛三郎
出版者
日本高圧力学会
雑誌
高圧力の科学と技術 (ISSN:0917639X)
巻号頁・発行日
vol.18, no.4, pp.321-327, 2008-11-20 (Released:2009-01-09)
参考文献数
28

We have carried out x-ray diffraction, small-angle x-ray scattering and high-resolution inelastic x-ray scattering measurements for supercritical fluid Hg accompanying the metal-nonmetal (M-NM) transition using synchrotron radiation at SPring-8. In these structural studies we have found an increase in the short-range correlation length and the dynamical sound velocity much faster than the adiabatic sound velocity in the M-NM transition region. These findings strongly suggest the existence of a peculiar fluctuation intrinsic to the M-NM transition in the fluid, which may reflect a first-order M-NM transition predicted by Landau, the winner of the Nobel Prize in physics.
著者
片岡 雅裕 橋山 智訓 田野 俊一
出版者
日本知能情報ファジィ学会
雑誌
日本知能情報ファジィ学会 ファジィ システム シンポジウム 講演論文集 第31回ファジィシステムシンポジウム
巻号頁・発行日
pp.350-353, 2015 (Released:2016-02-26)

推薦システムとは、履歴情報などを利用し利用者の好みにあうと思われる情報を提示するシステムである。推薦システムの発展により利用者の好みにあった情報を高い精度で取得できるようになった一方で、それ以外の情報に接触する機会が低下している。この状況はフィルターバブルと呼ばれ、気付かぬうちに接する情報が狭められる可能性がある。また選択的接触により情報に偏りが生じる可能性もある。選択的接触とは、人が情報を選択する際に好みに沿うものを選択しやすい傾向のことを言う。そのため閲覧する情報に偏りが生じる可能性がある。そこで本研究では利用者が閲覧する情報の偏りを気付かせる推薦システムのUIを設計する。
著者
烏帽子田 敬 勝海 一郎
出版者
特定非営利活動法人日本歯科保存学会
雑誌
日本歯科保存学雑誌 (ISSN:03872343)
巻号頁・発行日
vol.50, no.5, pp.570-581, 2007-10-31
被引用文献数
4

この研究の目的は,エンジン用器具で拡大形成を行ったことを前提にしたテーパーが6/100の樹脂製直線根管模型に,材質,サイズが異なる各種のスプレダーを用い側方加圧充填法による根管充填を行い,ガッタパーチャポイントの圧接状態を評価するとともに,評価方法を比較検討することにある.すなわち1種のステンレススチール製スプレダーDentalEZのStar Dental D11T(S-D11T)と6種のニッケルチタン製スプレダー〔RoekoのNiTi#15(R-15)とNiTi #25(R-25), NiTi #35(R-35)およびNiTi D11T(R-D11T),BrasselerのNaviflex NT D11T(B-D11T)とNaviflex NT 4SP(B-4SP)〕を用い,側方加圧充填法による根管充填を同一スプレダーごとに模型3個ずつ行った.圧接状態の評価は,根尖側6mmの根管壁面に残存する厚さ5μm以下のシーラーの占める割合(GP圧接率),マイクロフォーカスX線CT装置により撮影した根尖から1,2,3,4,5,6mmの全断層面におけるガッタパーチャポイントの占める割合の平均(GP/CT充塞率),根尖から1,2,3,4,5,6mmの全根管切断面におけるガッタパーチャポイントの占める割合の平均(GP総充塞率),各切断位置ごとのガッタパーチャポイントの占める割合の平均(GP位置充塞率)を求め評価するとともに,評価方法の比較検討を行うことにより以下の結論を得た.残存シーラーによるGP圧接率は,B-D11Tが92.1%と最も高く,次いでR-D11T,S-D11T,R-15とR-25,R-35の順で,B-4SPは57.9%と最も低い値を示した.マイクロフォーカスX線CT装置によるGP/CT充塞率は,S-D11Tが96.6%と最も高く,次いでB-D11T,R-D11T,R-25,R-35,R-15の順で,B-4SPは88.9%と最も低い値を示した.根管切断面によるGP総充塞率は, S-D11Tが97.9%と最も高く,次いでB-D11T,R-D11T,R-25,B-4SP,R-15の順で,R-35は90.4%と最も低い値を示した.根管切断面の切断位置によるGP位置充塞率は,S-D11Tが各切断位置で96.9%以上の高い値を示したが,B-D11TはS-D11Tよりも根管先端部での圧接がやや劣り,またR-D11T,R-25,R-15,B-4SP,R-35の順に,根管中ほどで充塞率が低下する現象がみられた.以上の結果より,S-D11T,R-D11T,B-D11Tは良好にガッタパーチャポイントの圧接を行うことができたが,R-35,B-4SPでは十分に圧接を行えないことがわかった.またマイクロフォーカスX線CT装置によるGP/CT充塞率と切断面によるGP総充塞率の評価法については,両者に統計学的な有意差は認められず,マイクロフォーカスX線CT装置による評価の信頼性,有用性が確認できた.

1 0 0 0 OA 刀劔押形

出版者
巻号頁・発行日
vol.[23],